SBIR/STTR Research Award

Rugged High-Resolution Xenon Gamma-Ray Spectrometer

Award identifier a0a47dae2bce290ee3e1bf38608e58ce4f16e4e9cef809e7152cb6b0cc7c528bAwarding agency Department of Energy

Award amount

$99,885

Program and phase

SBIR · Phase I

Award year

2002

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Energy
Branch
Not reported
Recipient company
Constellation Technology
Proposal award date
Not reported
Contract end date
Not reported
UEI
VF8LB3T79HQ5
Solicitation number
Not reported
Topic code
Not reported

Research abstract

70794 Monitoring the non-proliferation of nuclear weapons requires the detection of penetrating radiation emitted by nuclear materials (NM). Gaseous ionization chambers, based on collecting the charge produced by the ionizing radiation inside the detecting medium, are widely used to detect this radiation. To eliminate the dependence of pulse-height distribution at points of interaction, the volume of the ionization chamber is usually divided into two parts by a screening grid. However, signals read out from the gridded ionization chamber are extremely sensitive to micro-vibrations of the grid, leading to an additional low-frequency noise component. In addition, the grid makes the ionization chamber very fragile. This project will develop a rugged, high-resolution xenon cylindrical ionization chamber. Compared to conventional cylindrical ionization chambers with a screening grid, the proposed detector will be less sensitive to mechanical vibrations and acoustic noise, and will have a simpler design at a reduced production cost. At the same time, the new detector will retain a large size, large mass (several kilograms) of working medium, and excellent energy resolution (50 atm) Xe can provide the desired energy resolution. Commercial Applications and Other Benefits as described by the awardee: The proposed detector could be used to measure gamma rays and neutrons in nuclear material monitoring systems, special systems targeted to detect and identify the presence of weapon grade plutonium, in situ gamma-spectroscopy of liquid radioactive waste, well-logging, and gamma-ray imaging.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

18 SBIR/STTR records share this UEI (2000–2013). Reported award amounts total $2,524,265. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Energy, Department of Health and Human Services, National Aeronautics and Space Administration, Environmental Protection Agency, National Science Foundation, Department of Defense

Agency intelligence

Department of Energy

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.