SBIR/STTR Research Award

High Field Magnets for MRI Applications

Award identifier fd671ab04ccb8c856c85f9c20a36e5f04128d80a2091ca3b1eb7ab9480bd410bAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$3,204,300

Program and phase

SBIR · Phase II

Award year

2005

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Supercon, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
FPGJH4FB7XY9
Solicitation number
PHS2005-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): The specific aim of the Phase I and Phase II research program will be to design and build an "open", split pair coil, high field (>1 .5T), cryogen-free MRI magnet. The key innovation that will make this goal feasible is the development of an advanced, high performance, round high temperature superconductor capable of operation at 20 Kelvin. Operating at a temperature of 20K will allow cooling of the magnet by conduction with a mechanical cryocooler. A cryogen free system does not require the vacuum and cryostat space and therefore will allow the magnet designer to use a split pair coil configuration for an open system for easier access to the imaging subject and the central imaging volume. An open magnet also provides more patient comfort by removing the claustrophobic "tunnel" of conventional cylindrical superconducting magnets. The cryogen free structure might also allow the magnet to be used in the horizontal and vertical position, allowing imaging while the patient is in the standing position. The benefits of open, superconducting MRI magnets are being realized daily. In 1994 a superconducting GE open magnet system was installed at the Brigham & Women's Hospital. Since then researchers at the Harvard Medical School believe that the machine will pay for itself by increasing the speed and accuracy with which surgeons can do biopsies on cancerous tumors. Also, by allowing surgeons to biopsy tumors that cannot be diagnosed by conventional methods, the new technique could save patients not only the costs but also the pain and discomfort of needless or inappropriate therapies. Another application of an open MRI is the use in osteoporosis diagnosis. In this case, the calcaneum of the feet of the patient is placed into the MRI machine. Most patients examined are typically elderly with very little mobility and cannot withstand significant discomfort by positions required in the conventional MRI system. A split coil configuration would then allow a much easier and more comfortable access to the volume of interest.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

105 SBIR/STTR records share this UEI (1983–2012). Reported award amounts total $22,724,253. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Energy, National Science Foundation, Department of Health and Human Services, Department of Defense

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.