SBIR/STTR Research Award

Novel, Low Cost, High Gain, Micropattern Detector

Award identifier 678d0b2781be39fc04f5bf2bcf362a7f89c6b7b9fa4638fa50d67443b475abf6Awarding agency Department of Energy

Award amount

$99,984

Program and phase

SBIR · Phase I

Award year

2007

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Energy
Branch
Not reported
Recipient company
Integrated Sensors, LLC
Proposal award date
Not reported
Contract end date
Not reported
UEI
PLCMEHSALP93
Solicitation number
DE-PS02-06ER06-30
Topic code
26

Research abstract

provide a higher resolution capability for detecting, tracking, and analyzing high and low energy neutrons, gamma rays, low energy ion beams, etc. To address this need, this project will develop a hybrid solid state sensor with an electron amplification gain on the order of 1011, positional resolutions approaching 10 µm, good potential spectral resolution, and rise times in the range of nanoseconds to picoseconds. The device will combine the best of several different detector technologies ¿ such as micropattern/GEM devices, avalanche photodiodes, and silicon photomultipliers ¿ into a high resolution, environmentally rugged, and radiation resistant structure with order-of-magnitude performance advantages. Phase I will design and model the performance of this new detector for nuclear physics applications. A proof-of-concept design will be completed and numerical simulations will be performed. If successful, an aggressive device fabrication and test program will be conducted in Phase II. Commercial Applications and other Benefits as described by the awardee: The two most important commercial applications for the new radiation detector would be medical imaging and homeland security. Medical imaging applications include lower-cost higher-resolution detection from X-ray multi-slice CT imagers, digital X-rays, PET/CT, single photon emission computed tomography (SPECT), computed tomography angiography (CTA), scintillation mammography, and myocardial imaging. For homeland security, the detectors could be used for active and passive radiation detection systems, including portal, parcel, and cargo monitors/radiography.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

14 SBIR/STTR records share this UEI (2007–2023). Reported award amounts total $9,097,273. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Energy, Department of Health and Human Services

Agency intelligence

Department of Energy

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.