SBIR/STTR Research Award

Acoustic Device for Spine Surgery

Award identifier 41a65b7a7d6292880871d8640ab2f6071190f4359700b636b00fc0dc77189f25Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$78,988

Program and phase

STTR · Phase I

Award year

2008

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
SONOSCREW, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PHS2007-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): An Acoustic Device for Preventing Spine Surgery Complications A specific and immediate concern arises in spine surgery, where an inserted instrument can damage the structures around the spine. For example, a device can be advanced too far into the vertebral body, and can cause damage to the nearby spinal cord and spinal nerve roots. These complications occur despite the use of a variety of approaches that image the spine in order to ascertain instrument tip location, but require intra-operative patient exposure to ionizing radiation, usually in the form of radiographs, fluoroscopy, and computerized axial tomography scans. We propose to conduct a feasibility study to explore and develop a dynamic real- time interactive dev ice insertion system based on quantitative ultrasound, in conjunction with A-mode and B-mode imaging, as a means by which to achieve proper guidance and positioning of the instrument. Such a system does not require any ionizing radiation. The study involve s the conduct of experiments to acoustically determine the elastic properties of bone. In both cortical and cancellous bone, in vitro experiments are conducted on acoustic scattering, attenuation losses, elastic moduli, and the velocity of sound. Experimen ts are conducted to determine the optimal transducer characteristics that will provide satisfactory imaging results in bone. Ex vivo experiments are also performed on excised animal vertebral bodies and intact spines. Additional experiments will be perform ed to develop imaging criteria for distinguishing between marrow and cortex, as to what constitutes proper instrument positioning, when a complication has occurred, and how to detect the presence of imaging artifacts. PROJECT NARRATIVE The relevance of thi s study to public health is that the proposed acoustic device can improve the efficacy and safety of spine surgery procedures. The proposed acoustic device can guide the surgical instrument, reduce the need for ionizing radiation, and reduce complications.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.