SBIR/STTR Research Award

Simplified Pump Oxygenator for Pediatric Use

Award identifier 4540c48a667d5431da01515dea6b940ad9376e94ebcf0b0b28f7cbac0090f9b1Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$100,000

Program and phase

SBIR · Phase I

Award year

2001

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
ENSION Inc
Proposal award date
Not reported
Contract end date
Not reported
UEI
Y4P6UDJLXLN3
Solicitation number
Not reported
Topic code
Not reported

Research abstract

DESCRIPTION (Verbatim from the Applicant's Abstract): Cardiopulmonary Technologies, Inc. (CPT) has developed very efficient Active Mixing Membrane Oxygenator (AMMO) with an inherent ability to pump blood as it transfers gases. Currently, this device consists of 0.18 M2 of membrane surface area and pumps 3.0 Lpm of blood. CPT is proposing to alter its current AMMO design to meet the needs of newborn and infant sized patients (less than 5 kg body weight). Experimental evidence supports the feasibility of our design criteria for a pediatric device that would include: membrane surface area of 0.1 M2, rated gas transfer of 50ml/min., pumping capability of 1.0 Lpm, and priming volume of 25 ml. Another advantage of this device will be the incorporation of efficient cooling elements within the oxygenator unit, thus taking further advantage of the active mixing concept and eliminating the need for a separate heater/cooler manifold. This Phase I program is designed to demonstrate the feasibility of our concept. The aims of this program are to modify our current design to meet the needs of the smallest patients, fabricate pediatric-sized AMMO units, and perform sufficient in vitro and in vivo trials to evaluate system performance and suitability for the intended use. If successful, we believe that this CPT product would gain acceptance by pediatric perfusionists throughout the medical community. PROPOSED COMMERCIAL APPLICATION: Pediatric patients represent a substantial number of open heart operations each year. Current oxygenators are miniaturized versions of adult sized devices that have not been optimized for these patients. This device is especially designed to meet the needs of small patients and as the first oxygenator designed specifically for this population, coupled with its increased efficiency, should become the dominant device in this market.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

27 SBIR/STTR records share this UEI (2001–2025). Reported award amounts total $14,034,077. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Defense

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.