SBIR/STTR Research Award

Amniotic Membrane versus Pericardium in Reducing Glaucoma Drainage Tube Exposure

Award identifier 171251a9bc862073fc551d2e7cf6e0635c8db8ca264f348bada8da2184f88e17Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$997,132

Program and phase

SBIR · Phase II

Award year

2012

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
BIOTISSUE HOLDINGS INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
C4GJA1DTK7L1
Solicitation number
PA10-050
Topic code
NEI

Research abstract

DESCRIPTION (provided by applicant): Glaucoma drainage devices (GDDs) have widely been used in the treatment of high-risk refractory glaucoma. To avoid tube exposure, which may lead to serious eye infection, the implanted GDD tube must be covered by apatch graft traditionally made of either donor sclera or pericardium. However, these patch grafts still carry a high rate of progressive thinning and erosion, a complication that we speculate results from the lack of cellular infiltration from the surrounding host conjunctival stroma and poor integration of these patch grafts to the host tissue. We further speculate that a thicker version of cryopreserved amniotic membrane (AM), manufactured by Bio-Tissue, Inc., a 100%-owned subsidiary of TissueTech, Inc.,could offer better tensile strength, be suitable for tectonic support, and have biological activities to promote cellular infiltration by the surrounding host conjunctival stroma, thus reducing progressive allogeneic patch graft thinning/erosion. ThroughSBIR Phase I grant support (R43 EY19785), we have evaluated the thicker AM as an alternative patch graft for covering the GDD tube during the primary implantation. We further monitored the host cell interaction using anterior segment optical coherence tomography (OCT). We have successfully accomplished the proposed aims of the above studies which demonstrated the short-term stability/efficacy of AM in covering the tube in primary GDD surgery (Phase I- Aim 1), and confirmed the feasibility of using OCT to distinguish host cell infiltration into the AM after transplantation over the GDD tube (Phase I- Aim 2). In this Phase II application, we propose to conduct a prospective, controlled study to compare the long-term safety and efficacy of the thicker AM (AmnioGuard , Bio-Tissue, Inc, Miami, FL) to the pericardium (Tutoplast(R), IOP Inc, Costa Mesa, CA) in securing the GDD tube and reducing tube exposure and graft thinning in patients with high risk glaucoma. We will also study the risk factors that may contribute to GDD tube exposure. Accomplishment of this Phase II study will position AM as an effective alternative to the existing patch grafts to reduce tube exposure and enhance the success of GDD implantation while providing a better aesthetic appearance andallowing visualization of the tube in patients with high risk glaucoma. This will also allow the Company to expand its market space from ocular surface to glaucoma diseases. We speculate that such a graft might also have other clinical applications outside of covering GDD tubes. PUBLIC HEALTH RELEVANCE: Our proposed prospective, randomized and comparative study described in this Phase II application aims to demonstrate the clinical safety and efficacy of transplanting a thicker version of amniotic membrane (AM) as an alternative tectonic substrate to cover glaucoma drainage device (GDD) tubes. Through SBIR Phase I grant support (EY019785), we found that this thicker AM offers superior tectonic support and biological activity to promote integration by the host conjunctival stromal cells, thus reducing patch graft thinning/erosion. The completion of the study described herein will allow eye surgeons to adopt this new AM graft to improve surgical outcomes and prevent complications in GDD surgery forhigh risk glaucoma patients. This will also allow the Company to expand its market space and provide services to glaucoma indications.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

14 SBIR/STTR records share this UEI (2003–2016). Reported award amounts total $7,392,317. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.