SBIR/STTR Research Award

Early diagnosis of acute kidney injury by aptasensors

Award identifier c8c9bb468c0b19297e18f293115c2468c80d6ba7836e0c0d82f2d43e7fe3fd00Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$150,501

Program and phase

SBIR · Phase I

Award year

2013

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Aptalogic, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
EWN1YJ67XK31
Solicitation number
PA12-088
Topic code
NIDDK

Research abstract

DESCRIPTION (provided by applicant): Acute kidney injury (AKI) affects more than 10 million people worldwide each year with reported mortalities from 15 to 60% in different patient populations. However, methods are lacking to support the early diagnosis ofAKI that could lead to early intervention, improved therapy, better prognosis, and lower medical costs. For these reasons, the development of early diagnosis tools for AKI is one of the solicited research topics listed by the NIDDK. Our ultimate goal isto develop a portable device for reliable early detection of AKI at point of care. The innovation of our proposal lies in the combination of aptamer technology with microcantilever detection of serum/urine neutrophil gelatinase-associated lipocalin (NGAL),an early marker of AKI [2-4 hours at the onset of AKI with cutoff concentration of ~ 150 ng/ml (6.8 nM)]. Aptamers are ssDNAs/RNAs that bind their targets avidly and specifically, and are selected in vitro by Systematic Evolution of Ligands by EXponentialenrichment (SELEX). For biosensor development, aptamers have many advantages over antibodies, including their smaller size, amenability to chemical synthesis and modifications and adaptability to a broad range of assay formats including a microcantileverdetection system. A microcantilever is a beam, often of silicon, that is 1-5 m thick and 500-100 m long and anchored only at one end. The microcantilever bends when its surface stress changes due to the conformation change that occurs upon ligand-receptor (e.g. aptamer-target) interaction on its surface. The differential surface stress between a reference cantilever coated with a scrambled nucleic acid that does not bind the analyte and a sensing cantilever coated with an aptamer that binds the analyte ismeasured by interferometry. In this phase I study, we propose two specific aims: 1. Identify 2'F-modified aptamers that bind NGAL specifically with nanomolar affinity. 2. Demonstrate an aptamer-functionalized microcantilever device for NGAL detection.In phase I, we expect to develop a prototype of an aptamer-functionalized microcantilever that will be responsive to NGAL, which will be further optimized in phase II for reliable performance with serum and urine samples with robust signal/noise ratio, sensitivity, detection limit and dynamic range of measurement and that can be used at point of care to monitor for AKI. PUBLIC HEALTH RELEVANCE PUBLIC HEALTH RELEVANCE: Acute kidney injury (AKI) affects more than 10 million people worldwide per year with 15-60% mortality. However, methods for early diagnosis of AKI are still lacking and consequently this is one of the research topics solicited by the National Institute of Diabetes and Digestive and Kidney Diseases. We propose to develop aptamer-based biosensors for early diagnosis of AKI at point of care, based on NGAL, an early marker (as early as 2-4 hours) for AKI.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

11 SBIR/STTR records share this UEI (2001–2019). Reported award amounts total $4,338,423. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Energy

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.