SBIR/STTR Research Award

Triazolopyrimidine Coated Endovascular Stent

Award identifier d096a2dbf801b3cb8cbd802f6a15f911c589cc715641f39333a9b1b795d624fbAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$106,559

Program and phase

SBIR · Phase I

Award year

2005

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Icon Interventional Systems, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PHS2005-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): There is a need for the further development of endovascular stents that inhibit stenosis as well as restenosis after angioplasty. There are a number of stents currently in clinical trials and the most effective have been the class of drug-eluting stents. However, there are concerns with the potential medical complications in patients with current drug-eluting stents. Icon Interventional Systems, Inc. has interest in this market and has been developing a coated, metallic stent that releases the biologic chemical, triazolopyrimidine. Our hypothesis is that triazolopyrimidine, can be delivered locally to coronary arteries after angioplasty and by its controlled release, have the ultimate goal of preventing in-stent stenosis and/or restenosis. The specific aims of the proposed project are: (1) to demonstrate that a metal stent could be coated uniformly with varying masses of triazolopyrimidine, followed by a proprietary parylene barrier, providing a mechanism for controlled release; (2) to determine the release kinetics of triazolopyrimidine in vitro by spectrophotometry and HPLC methodologies; (3) to determine in vitro and in vivo biocompatibility and efficacy of triazolopyrimidine and parylene using appropriate cell and animal models. At the end of this Phase I plan, we will have demonstrated that triazolopyrimidine can be coated on a metal stent followed by a uniform coating of parylene, which does not disrupt or delaminate upon expansion, and that a parylene barrier over the triazolopyrimidine coating on the metal stent provides a sustained release of drug. Controlled release of triazolopyrimidine from stents should provide anti-proliferative, anti-migratory and non-toxic effects on smooth muscle cells or endothelial cells in vitro. In vivo biocompatibility tests will show that parylene and triazolopyrimidine are biocompatible. Our intention is to obtain sufficient information to allow us to proceed to Phase II in which further studies to improve upon on the coating procedure and effective drug release to validate the effect in an in vivo model of angioplasty using a porcine model.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.