SBIR/STTR Research Award

MRI Compatible Electrode Catheter System

Award identifier f476ffa096c1f00524d817d829e12bd47a2a8b9e9f0391639da224cbd55e63d0Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$919,149

Program and phase

SBIR · Phase II

Award year

2008

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
IMRICOR MEDICAL SYSTEMS, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
QH9CXSFBTDR9
Solicitation number
PHS2007-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Atrial fibrillation and ventricular tachyarrhythmias occurring in patients with structurally abnormal hearts are the most important arrhythmias in contemporary cardiology.1-3 they represent the most frequently encounter ed tachycardias, account for the most morbidity and mortality, and, despite much progress, remain therapeutic challenges. Invasive studies of the electrical activity of the heart (electrophysiologic studies) are often used in the diagnosis and therapy of a rrhythmias and many arrhythmias can be cured by selective destruction of critical electrical pathways with radiofrequency (RF) catheter ablation. Attempts at applying ablation to atrial fibrillation and ventricular tachycardia have been made. Success has b een limited, however, by the long time duration of procedures, resulting from the difficulty of creating continuous linear lesions in a setting where areas of ablated myocardium cannot be directly visualized. Continuous linear lesions, without gaps, can bl ock critical arrhythmogenic circuits and reduce the amount of electrically contiguous arrhythmoginic substrate, thereby eliminating arrhythmias. We hypothesize that magnetic resonance imaging (MRI), with MRI-compatible diagnostic and therapeutic systems; c an allow electrophysiology studies and catheter ablation to be performed without x-ray radiation. We also hypothesize that this technology will provide the ability to visualize ablation lesions, which should greatly simplify production of continuous linear lesions, and should improve the effectiveness of ablation procedures in general. In addition to electrophysiology, these methods may be applicable to guiding other diagnostic and therapeutic techniques. In Phase I, we completed a prototype steerable ablat ion catheter that has allowed us to target any area of the endocardial surface of the heart. We also developed integral filters for protecting the catheters from excessive heating during MR imaging. We tested the prototype catheters in animals to show that electrophysiology studies can be done under MR guidance alone, that lesions can be produced and imaged, that linear lesions can be produced, and that MRI has sufficient resolution to allow detection of significant gaps in the lesions. In Phase II, we will develop, test, and prepare for manufacturing and marketing an improved, clinical-grade version of the ablation system, and apply for FDA approval for testing the technology. The improved, clinical-grade catheter system will incorporate all capabilities pr eviously tested individually. The improved catheter system will both ablate cardiac tissue and sense cardiac activity. The improved catheter will also have improved filtering and shielding to allow all current clinical MRI pulse sequences to be used for im aging. Further, the improved catheter system will have sensors incorporated into the tip of the catheters to allow accurate determination of the position of the catheter tip, enabling real-time manipulation of the imaging plane to always include the cathet er tip. Finally, the improved catheter system will incorporate temperature sensors for monitoring ablation temperatures at the catheter tip. Rhythm abnormalities of the heart, where the heart beats too fast, affect millions of people in the United States. These abnormalities can cause substantial symptoms and/or death, and some can be cured by cauterizing (ablating) a small portion of the heart. Methods are being developed to use the real-time and high quality imaging of Magnetic Resonance Imaging to improv e substantially the safety and efficacy of these ablations, as well as extend these methods to procedures involving other organ systems.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

2 SBIR/STTR records share this UEI (2008–2020). Reported award amounts total $1,318,688. Reported amounts are not federal obligations.

Phases: Phase II, Phase I

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.