SBIR/STTR Research Award

Temperature-Tolerant COLD-PCR enables mutation-enriched targeted re-sequencing

Award identifier 2830be8a17a66519b3e0a590da6d0bc843b8ea12ce312e518e93095e4c42bdcaAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$212,770

Program and phase

SBIR · Phase I

Award year

2013

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
ACTUATED MEDICAL, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
VG84D4KN5LR5
Solicitation number
PA12-088
Topic code
NICHD

Research abstract

DESCRIPTION (provided by applicant): This Phase I SBIR develops and tests the active Pedi ET-Clear system to clean mucus from 2.5 mm diameter neonatal endotracheal tubes with significantly reduced deleterious impact on lung function and mechanics, as compared to current methods. Actuated Medical, Inc. is an ISO 13485-certified medical device developer integrating active motion technologies into advanced medical devices. Public Health Problem: Endotracheal tubes (ETT) are placed in a patient's trachea when they are unable to breathe on their own. A major complication of an ETT is the buildup of secretions from the lungs, with a particular concern for Ventilator Acquired Pneumonia (VAP). Respiratory secretions in ETTs are estimated to impact 107,000 neonatal and 900,000 total patients annually in the U.S. The most common and fatal infection in the ICU is VAP. VAP increases ventilator days, critical care and hospital lengths of stay. To remove mucus, the ETT is suctioned with a suction catheter, potentially after being flushed with saline. Risks associated with suctioning include hypoxia (low oxygen in blood), bradycardia (low heart rate), or atelectasis (collapse of part of the lung). Suctioning is often required every 1 to 4 hours and strains the lungs of an already compromised patient. Lung volume is reduced by the suctioning and results in impaired gas exchange and potential lung collapse. Neonatal ETTs, with inner diameters as narrow as 2.5 mm, require frequent suctioning and are difficult to clean without obstructing the airway. A device is needed for cleaning neonatal tubes quickly, while minimizing the suction pressure required and maintaining volume in the patient's lungs. Phase I Hypotheses: Pedi ET-Clear Alpha prototype demonstrates superior safety (e 50% improvement in retained lung tidal volume) and superior efficacy (cleaner ETT in the same amount of time) compared to standard suction catheter in 2.5 mm ETTs. Hypothesis testing will be performed with = 0.05 and 0.20. Phase I Specific Aims: Aim 1Finalize Closed System Design and Construct Alpha-II Prototypes for Optimization Testing (Month 1 - 4). Aim 2 Optimize Pedi ET-Clear Parameters for Rapid Mucus Removal with Minimal Effect on Lung Tidal Volume Compared to Baseline Impact of Current Suctioning Methods (Month 5 - 6). Aim 3 Final Testing of Pedi ET-Clear Performance Compared to Standard Care with Neonatal Clinicians in Closed Ventilation Test Model (Month 6). PUBLIC HEALTH RELEVANCE PUBLIC HEALTH RELEVANCE: A patient is intubated with an endotracheal tube and connected to a ventilator when they cannot breathe on their own. Mucous builds up over time in the tube, and must be suctioned out. Neonatal endotracheal tubes, with inner diameters as narrow as 2.5 mm, require frequent suctioning and are difficult to clean without obstructing the airway. The suctioning puts additional stress on the lungs of an already compromised patient. A device for cleaning endotracheal tubes, particularly pediatric and neonatal tubes, without the negative impacts of current suctioning methods, will be of great benefit.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

53 SBIR/STTR records share this UEI (2008–2024). Reported award amounts total $43,582,989. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, National Science Foundation, Department of Defense, National Aeronautics and Space Administration, Department of Agriculture

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.