SBIR/STTR Research Award

High-Voltage Compact Capacitor for Implantable Defibrillator

Award identifier a22d934ec8e253e868dfe2ab2b362c9abdd68264a044c9f1faeebb42449abbd0Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$789,262

Program and phase

SBIR · Phase II

Award year

2009

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
GINER INC
Proposal award date
Not reported
Contract end date
Not reported
UEI
ULB2NMDNXC69
Solicitation number
PHS2009-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): High Voltage Compact Capacitor for Implantable Defibrillator: Worldwide, sudden cardiac arrest is a major health problem. The use of Implantable Cardioverter Defibrillators (ICD) has become an increasingly accepted treatment option, one that could save thousands of heart attack patients annually. With the increase in acceptance of these devices, the drive for improvement of function and materials has intensified. One of the most critical and vital components of the ICD device is a high-voltage capacitor. The function of the capacitor is to store energy over a period of seconds and deliver it to the heart over a period of a few milliseconds. The overall goal of the proposed project is to develop an integrated and unitized (all elements in intimate contact), miniaturized, and all-solid high-voltage capacitor for the next generation of implantable defibrillators. The all-solid high-voltage capacitor is attractive because it can store several times as much energy as a conventional electrolytic capacitor, while retaining the ability to deliver that energy at high discharge rates. It will also allow the stacking of multi-cell units in series in the same package, something not possible in the case of the liquid electrolyte, which requires complicated packaging. This will reduce the number of required capacitors inside the ICD to two, reduce the ICD weight and volume by replacing liquid electrolyte with solid electrolyte, permit use of a bipolar multi-cell series design to achieve high voltages, and, eliminate any possibility of shunt currents and electrolyte leakage, thereby enhancing reliability and safety. The feasibility to develop an advanced miniaturized and all-solid high-voltage capacitor for the next generation of implantable defibrillators was demonstrated in Phase I. Improved tantalum anode formation processes enabled us to form anode components successfully at high voltages up to 350 V, which lead us to believe that even higher voltage can be achieved. During this Phase II program, it is proposed to build full-size 700-V stacks to be studied under long-term and accelerated test conditions. Based on the Phase I results, the technical approach for the Phase II product development program will include 1) further optimization of the tantalum anode structure b) fabricate final cell stacks, evaluate capacitor housings, encapsulation materials, and procedures, b) perform long-term stability and biocompatibility tests, and to, c) Study and select sterilization and packaging options. The successful completion of the Phase II project will result in a miniaturized capacitor and a method of fabricating a novel all-solid capacitor which will have applications for ICDs. PUBLIC HEALTH RELEVANCE: The use of Implantable Cardioverter Defibrillators (ICD) has become an increasingly accepted treatment option, one that could save thousands of heart attack patients annually. There is critical need for reduced size, high energy density capacitor for the ICD. Substantial reduction in the volume and consequently weight of the capacitor inside the ICD would represent a significant product improvement ICD resulting in many advantages for the patients.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

447 SBIR/STTR records share this UEI (1983–2025). Reported award amounts total $147,003,828. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Defense, Department of Health and Human Services, Department of Energy, National Aeronautics and Space Administration, National Science Foundation, Department of Agriculture

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.