SBIR/STTR Research Award

2-Clinic Feasibility Study: Inverse Scatter Breast Scan

Award identifier e6e7007523eb30f4146722afe5ca5bf5d4eb5d1b2d1bc60193c4f27f0660e845Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,660,040

Program and phase

SBIR · Phase II

Award year

2007

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
TECHNISCAN, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): This Phase-l SBIR project, of a Fast Track pair, will provide concept testing, computer simulation studies, laboratory-based hardware emulation and a final specification for the final scanner to be constructed in the Phase ll SBIR project. The result of this Fast Track effort is intended to be used as the foundation, starting specifications and design for the construction and clinical testing of a pair of advanced, second-generation, "Ultrasound CT(tm)" breast cancer detection and diagnostic scanners. No construction of scanner components will be done during Phase-l. During Phase-ll, these two second generation scanners would be installed at Mayo Clinic and at the University of California at San Diego Hospital. These second generation scanners include improved features over TechniScan's first generation scanner that was installed in a local cancer center in August 2004. The first generation scanners consist of two opposing, but parallel, 2-D transducer arrays that rotate about a pendent breast in a water tank. The arrays also are moved vertically after each 360 degree rotation. Inverse Scattering, 3-D, Tomographic images were computed for sound speed and acoustic attenuation. Since August 2004 new transmit and receiver arrays are being incorporated. To these capabilities the second generation scanner adds: (1) improved inverse scattering in-plane spatial resolution and signal to noise ratio by beam shading and by relative rotation between transmit and receiver arrays; (2) improved inverse scattering spatial resolution by tilting the arrays in a vertical direction; and (3) improved reflectivity imaging by adding a commercial OEM beam former.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.