SBIR/STTR Research Award

Overcoming limitations of breast volume imaging in 3D dedicated mammotomography

Award identifier 8575151bf6a987f992a7707dadcb75a70363f1c3c972bf302daddd2b52461febAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$100,000

Program and phase

SBIR · Phase I

Award year

2007

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
ZUMATEK, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): The emergence of compact, high-quality digital X-ray imaging detectors, together with nearly exponential growth in computing power and corresponding price reductions, allows for the potential of dedicated 3D breast imaging. X-ray mammography (XRM) has recognized limits including relatively high false negative rates. Other disadvantages include breast compression, relatively high dose to the breast, and low positive predictive value, especially for radiographically dense breasts. The dedicated breast Computed mammoTomography (CmT) solution we are proposing has the potential for improved detection of breast lesions through the removal of contrast-reducing overlying tissue, as well as the added benefits of uncompressed breast imaging for greater patient comfort, and breast dose equal to or less than that of current dual view mammography. Ultimately, we expect this technology to result in improved positive predictive value with earlier cancer detection and reduced morbidity and mortality. In the long term, we seek to demonstrate the feasibility of this device in a clinical setting by overcoming the current limitations in imaging the full breast volume and chest wall. These physical limitations are currently imposed by the fact that the X-ray tube and detector must trace an orbital path which includes moving under a patient support. For other "standard" designs, this makes it difficult to image close to the chest wall, though our prototype device has the 3-dimensional positioning capability to potentially overcome some of these limitations. Specific Aim 1 will investigate of partial angle tomographic scanning using the patient bed to move the breast further into the field of view to capture the entire breast and chest wall while limiting the orbit of the device to the sides of the bed. The assembly will be placed under a patient bed at the Multi-Modality Imaging Lab (MMIL) at Duke University Medical Center and partial angle scans made of available torso, breast, and lesion phantoms. Observers will determine the extent of visibility of lesions close to the chest wall. Specific Aim 2 will demonstrate the feasibility of utilizing current patient bed vertical elevation capabilities to change the relationship between breast and system center of rotation during scans to provide full 360 degree acquisitions while avoiding patient bed limitations. A patient bed with multiple degrees of freedom of movement will be used to lower the patient phantom further into the field of view while the device is perpendicular to the bed axis, then raise the bed to allow to device to move under the bed. Results will be evaluated as in Specific Aim 1. Specific Aim 3 will model patient bed designs to determine the degree to which the chest wall can be moved into the field of view with reasonable patient comfort by potentially utilizing smooth bed contours around a patient's hips and head. Successful implementation of the above alternatives, pending results of Phase I, will result in a next generation advanced system being produced in Phase II that can be placed in a clinical setting for the beginning of patient studies, leading to a commercially available product.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.