SBIR/STTR Research Award

ULTRA-HIGH RESOLUTION ACOUSTIC MICROSCOPY

Award identifier b8f4a5abf273b36b3cd3aafdf62ba557a147b760ed15d47549291601cfca7844Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$336,986

Program and phase

SBIR · Phase I

Award year

2002

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
J&W Medical LLC
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

A novel, broadband scanning acoustic microscope (SAM) for in vivo imaging and characterization of micro-cellular biological tissue structures is proposed. It will operate at a frequency of 4.0 GHz, which offers a resolution of less than 0.4 microns, orders of magnitude less than that commercially available for medical diagnostic and non-destructive testing applications. The transducer will be fabricated by two methods: (1) utilizing a sol-gel process to grow the element as a single crystal, and (2) forming the element with pulsed laser deposition (PLD). Each pixel of an acoustic C-Scan image will provide information about the absorption, elastic properties and density of tissue cells, which may improve the visualization and clinical assessment of consistent patterns of cellular malignancy. The C-Scan image will be formed with a novel technique that utilizes a piezoelectric actuator for precise and reliable micro-stepping in a raster format for data acquisition and image presentation. A feasibility assessment of the clinical utility of the proposed design will be carried out at Thomas Jefferson University Hospital (Philadelphia., PA). Acoustic images will be taken of a wide variety of normal tissue specimens and the measured acoustic features compared with those obtained with standard transmissive and reflective optical techniques for tissue characterization. Proposed Commercial Application: A 4.0 GHz acoustic microscope offer significant benefits for both medical and material science applications. If successful, Layered Manufacturing Inc. is prepared to license the technology to all interested ultrasound system companies.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.