SBIR/STTR Research Award

Low Cost High Frame Rate Detector for Macromolecular Diffraction and Scattering

Award identifier bc742c98cfa1f768daae5b079bd61475f59fef3d3b12612850bf2cc84c6fb88eAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$136,816

Program and phase

SBIR · Phase I

Award year

2009

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
RADIATION MONITORING DEVICES, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
SCKQA85YU4U4
Solicitation number
PHS2009-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Advanced photon sources are capable of providing extremely high X-ray intensities and have proven to be outstanding resources for X-ray scattering and time-resolved diffraction of materials such as organic semiconductors used in electronics, photodiode, and photovoltaic applications, and biological materials such as non-crystalline biological systems. The problem, however, is in finding a detector that can provide multiple frames of detailed structural information on the required millisecond time scale with high spatial resolution, high sensitivity and large area. Recent detector designs address some of these requirements, but none satisfies all - yet they are prohibitively expensive. Development of new and cost-effective detectors that can simultaneously address all of these demanding needs is the key to fully exploiting these outstanding new X-ray sources. To address these limitations we propose to develop a novel X-ray imaging detector that can simultaneously provide millisecond time resolution, high spatial resolution, large imaging area, sensitivity to detect individual low energy X-rays above the noise, and wide dynamic range, all at a very low cost compared to current detector systems. Our approach is to take advantage of revolutionary new developments in low-cost readout sensors and mitigate their limitations through the use of novel system components such as an advanced new scintillator from RMD. The goal of the Phase I research is to demonstrate the feasibility of developing such a detector for synchrotron applications. Specifically, we will develop technologies to fabricate the new scintillator with the desired properties and integrate this sensor with a high-speed readout to form a prototype detector. The detector thus produced will be thoroughly evaluated in our laboratory as well as at the Advanced Photon Source (APS) at Argonne National Laboratory to establish its sensitivity, resolution, and speed of operation. The Phase II project will build on the Phase I research and will seek to develop and deliver a fully functional large area detector for macromolecular diffraction and scattering studies to be performed at the APS synchrotron beamline. Beside its exceptional value in critical time-resolved X-ray diffraction and scattering studies of biological systems, this detector will find widespread use in many areas of medical imaging, high speed computed tomography, non-destructive testing, and basic physics research. Due to its high performance, compact nature and very low cost, the proposed detector will be ideally suited for homeland security applications ranging from baggage scanning to detection of biological agents without contaminating the detector system. PUBLIC HEALTH RELEVANCE: The proposed research will develop a novel X-ray imaging detector that can simultaneously provide millisecond time resolution, high spatial resolution, large imaging area, sensitivity to detect individual low energy X-rays above the noise, and wide dynamic range, all at a very low cost compared to current detector systems. Our approach is to take advantage of revolutionary new developments in low-cost readout sensors and counterbalance their limitations through the use of novel system components such as an advanced new scintillator from RMD. The availability of such a sensor will enable advancements in the high speed X-ray imaging detector technology needed for many critically important biological studies such as static and time- resolved scattering from macromolecules, high speed computed tomography, etc.

Technology keywords

Not reported

Research funding history

930 SBIR/STTR records share this UEI (1983–2026). Reported award amounts total $346,950,619. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Energy, Department of Health and Human Services, Department of Defense, National Aeronautics and Space Administration, National Science Foundation, Department of Homeland Security

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.