SBIR/STTR Research Award

Infant Breath

Award identifier 45223c94d2dd883b651c02ccdb8fa9c66839648690ecd5a0dc228f0f68d586bcAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$149,939

Program and phase

SBIR · Phase I

Award year

2011

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
AGILTRON, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
K33SCYLG8EN1
Solicitation number
PA10-050
Topic code
NICHD

Research abstract

DESCRIPTION (provided by applicant): The overall goal of this proposed research is to adopt an inexpensive IR camera and image analysis software for non-contact monitoring the breath of a premature infant. Sleep apnea in these patients can lead to significant health problems, even death. Existing sensors can give false signals. An all optical system that can detect CO2 in the baby's breath without any piece of the apparatus touching the patient can give more reliable results with greater patient comfort. The proposed Phase 1 research program will test the hypothesis that a dual wavelength imaging camera can discern the breath plume of a small infant. This has been demonstrated for an adult but the infant's breath has a much smaller gas volume and much fasterbreathing rate. Agiltron's optical expertise has an innovative design for this imaging system that will increase signal to noise levels and allow unambiguous detection of the more difficult target. The camera system will be assembled and tested on a simulator but also on at least 2 infants to show feasibility with the high variability of actual breath. If this preliminary feasibility study is successful, then the Phase 2 effort would conduct preliminary clinical trials for improved statistics with a highlyvariable parameter demonstrating that not only can the camera see breath, but it can determine when an infant stops breathing normally. If successful, an inexpensive system would be designed and tested for monitoring such infants at the hospital and in the first month(s) at home. PUBLIC HEALTH RELEVANCE: If sleep apnea (cessation of breathing) in infants is detected quickly, intervention by a caregiver can prevent severe health issues, possibly even death. Motion monitors are now used but existing instrumentation can give false signals due to obstructive breathing and/or has adverse reactions with the infant for long term use. This research proposes to develop a non-contact sensor to detect exhaled carbon dioxide providing more reliable indication ofbreathing with reduced stress on the patient.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

234 SBIR/STTR records share this UEI (2001–2017). Reported award amounts total $47,152,840. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense, Department of Energy, National Aeronautics and Space Administration, Department of Health and Human Services, National Science Foundation, Department of Homeland Security

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.