SBIR/STTR Research Award
Multiplex Microarray for the Detection of Pre-Type 1 Diabetes Autoantibodies
Award amount
$840,406Program and phase
SBIR · Phase IIAward year
2008Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- PULSAR CLINICAL TECHNOLOGIES, INC.
- Proposal award date
- Not reported
- Contract end date
- Not reported
- UEI
- Not reported
- Solicitation number
- PHS2007-2
- Topic code
- Not reported
Research abstract
DESCRIPTION (provided by applicant): This SBIR project addresses an important medical need for improved, new technology-based assays for detecting autoantibodies relevant to Type 1 diabetes (T1D). T1D affects a million Americans and its incidence is incre
asing at an alarming rate of 2 to 5% per year. In T1D, circulating autoantibodies against islet cell antigens reflect the process of autoimmune destruction of the insulin-producing beta cells. Auto antibodies are clinically useful because they are present
early in the immune process, often years before patients develop hyperglycemia and can be used as markers to identify individuals at risk for T1D and to predict risk, particularly when autoantibodies against multiple antigens are present. Current assays, b
ased on radio immunoadsorbant (RIA) or enzyme linked immunoadsorbant assays (ELISA) methods test for one antibody per assay and are cumbersome, expensive, and some have poor inter-laboratory reproducibility. Recently, a single ELISA assay that is used to d
etect two antibodies simultaneously but cannot assign antibody specificity became available. New intervention strategies for T1D prevention depend on early detection of pre-T1D and sensitive and reliable analytical techniques are crucial. The Phase I feasi
bility studies of a new multiplex protein microarray assay, based on our novel colloid technology to simultaneously and specifically detect three autoantibodies i.e. IAA, GAD-65 and IA-2 that are informative for T1D risk, have been very successful. In Phas
e II, we will develop the T1D- Autoimmunity Array Testing System for clinical diagnostic use. The fully integrated system will include disposable assay biochips, an automated processing station that includes a low cost fluorescence reader, sample trackin
g and analytical soft-ware. At the successful conclusion of Phase II, we will have developed protocols, procedures and the fundamentals of product specifications that will form the basis for production design of the T1D- AutoimmunityArray Testing System
as a low cost, reliable, accurate testing product that meets the requirements of a broad range of clinical and research environments. PUBLIC HEALTH RELEVANCE: Prediction of T1D through antibody testing is critical for the proper identification of at-risk
subjects and for risk quantification. In T1D, despite the higher risk in relatives, 90% of new cases are sporadic cases occurring in families with no prior family history. Thus, in the absence of the capability to screen populations at large, most children
with T1D do not have the opportunity for early treatment unless they are screened because they are related to someone with the disease. Clearly, new assays with a better cost-benefit profile are needed to extend the benefit of autoantibody testing to the
majority of individuals who develop T1D and other autoimmune diseases. A multiplex microarray methodology that would allow testing for numerous significant T1D autoantibodies should also allow for early identification of asymptomatic individuals and provid
e better chances of preventing disease.
Technology keywords