SBIR/STTR Research Award

Advanced Plate Osteosynthesis Technology to Promote Healing of Bone Fractures

Award identifier 36e8218323083b8ade491a82f248996b1bee899b6831e3b6e0f99a28097ed801Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$148,448

Program and phase

STTR · Phase I

Award year

2012

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Apex Biomedical Company, LLC
Proposal award date
Not reported
Contract end date
Not reported
UEI
RNNPANMTT5T6
Solicitation number
PA11-097
Topic code
NIAMS

Research abstract

DESCRIPTION (provided by applicant): Each year, over 6 million fractures are treated in the United States at a cost in excess of 13 billion. Between 5-8% of these fractures experience complications, particularly in the steadily increasing population withosteoporosis. By providing better fixation in osteoporotic bone, locked plating technology has rapidly transformed fracture treatment with bone plates. Over the past decade, locked plating captured 88% of the 1.1 billion US plating market, despite the virtual absence of clinical data supporting improvements in outcome. However, the wave of enthusiasm has been tempered by failure rates of 13-21% reported in recent clinical studies on locked plating. Research has confirmed that deficient fracture healing observed with locking plates is largely due to their inherent stiffness, which suppresses interfragmentary motion required to stimulate bone healing by callus formation. The proposed research will assess the feasibility of an innovative locked plating strategy aimed at resolving the growing concern of non-unions with current locked plating technology. Our proposed product is an elastic locking plate (E-Lock plate) with flexibly suspended screw holes that permit controlled motion at the fracture site to actively promote fracture healing by callus formation. This feasibility study will test the hypothesis that E-Lock plates can deliver controlle interfragmentary motion within the range known to promote fracture healing, while providing fixation strength comparable to that of a standard locked plating construct. For this purpose, the preliminary E-Lock plate design will be computationally optimized to deliver the required stiffness and interfragmentary motion for promotion of callus formation, while maximizing construct strength. The optimized solution will be translated into functional prototype E-Lock plates for bench-top testing. E-Lock plating constructs will be tested in direct comparison to standard locked plating constructs in all principal loading modes.Results of this research will be essential to translate this promising technology into an advanced fracture treatment, particularly for treatment of osteoporotic fractures in the elderly population. Successful completion of this research will determine thefeasibility of E-Lock technology to actively promote fracture healing while retaining the improved fixation strength of locking plates. This technology will furthermore be poised to prevent non-unions by reducing the staggering non-union rate associated with standard locking plates in the over 200,000 patients that are treated each year with locking plates in the United States alone. PUBLIC HEALTH RELEVANCE: By providing superior stabilization of bone fractures, locking plate technology has beenimplemented in 88% of all bone plates, but recent studies indicate that these locking plates are too stiff and suppress fracture healing, requiring revision surgery i approximately one out of five patients. The proposed research evaluates the feasibility of an innovative design that makes locking plates less stiff and that can actively promote fracture healing. If this novel technology can be successfully transferred into a commercial solution, it will reduce the staggering cost and societal burden caused by deficient fracture healing in over 200,000 patients that are treated each year in the USA with locking plates.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

7 SBIR/STTR records share this UEI (2010–2021). Reported award amounts total $4,203,735. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.