SBIR/STTR Research Award

CRYO-COIL HR-MAS PROBE FOR SNR IN NMR OF TISSUES

Award identifier ac2ba6fbf6b0f4e8645ebedb0c46cb6d6925f6c8172a3d0cf5a0b54dcac63ce7Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$208,852

Program and phase

SBIR · Phase I

Award year

2002

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
DOTY SCIENTIFIC, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
ZEWHLT5Y7H33
Solicitation number
Not reported
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): Recently, Magic Angle Spinning (MAS) has been combined with high-field high-resolution Nuclear Magnetic Resonance (HR-NMR) to extend the technique to inhomogeneous systems, such as human and animal tissues. The 1 H HR-MAS spectrum of malignant breast cancer tissue shows dramatically increased levels of phosphocholine compared to nonmalignant breast tissue, and it appears likely that other unambiguous markers can be identified for many other pathologies if the signal to noise ratio (SNR) of the HR-MAS probe can be increased sufficiently. HR NMR probes for liquids have very recently become available with cryogenically cooled sample coils that promise to revolutionize the field of NMR owing to their factor-of-four improvement in SNR. Similar improvements in SNR may be possible in HR-MAS. The engineering challenges of developing a cryo-coil HR-MAS probe appear substantial but not insurmountable, and they will be systematically addressed in the proposed research. Preliminary circuit, computational fluid dynamics (CFD), and thermal analyses show that a combination of (1) a novel approach to quad-resonance MAS (1 H-I 3C-2H-I 5N) with all of the critical circuit elements maintained at -35 K, (2) integrating a ceramic dewar into a novel sample spinner design, and (3) cryogenic preamps offers the potential for a factor-of-three increase in SNR in a cryo-coil HR-MAS probe at fields up to 800 MHz. Prior work in our group with cryo-sample CP-MAS probes has established the viability of the proposed approach. This Phase I project will demonstrate feasibility of a dewared MAS spinner design with a high-efficiency quad-resonance cryogenic circuit. NMR experiments will be performed in a 7 T magnet with the sample at room temperature and the circuit at -90 K to validate essential features of the cryogenic system design. Phase II will complete the developments necessary for quad-resonance cryo-coil HR-MAS with pulsed field gradients at fields up to 18.8 T (800 MHz). Initial field testing at an outside institution is expected by the end of Phase II.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

44 SBIR/STTR records share this UEI (1985–2025). Reported award amounts total $25,710,711. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Defense, National Science Foundation, Department of Energy

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.