SBIR/STTR Research Award

Implantable glucose sensor with prolonged accuracy

Award identifier b73e4b7adc0b31ff69fdfe6eb1f2ebd6fcbfc102f2098f617adbab5a205f76acAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$806,213

Program and phase

SBIR · Phase II

Award year

2008

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
MICHIGAN CRITICAL CARE CONSULTANTS, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
NVSPCRHNAF11
Solicitation number
PHS2007-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): The goal of this study is to fabricate an intravascular glucose sensor that functions accurately for 7 days in vivo. We will utilize a glucose membrane design devised in Phase I to develop a custom outer membrane that has covalently attached bioactive sites to resist biofouling, allows for suitable glucose diffusion, and prevents leaching of potentially toxic by-products. This membrane will be applied to needle-type, amperometric glucose sensor. The versatility of the s ensor design will allow easy incorporation into a patient's bloodstream through a central access catheter. The catheter will be designed for 7 day use in the intensive care unit, and will be complete with a hemostatic connector for attaching to an access l ine, and the electrical connections to an amplifier/display unit. The final prototype will be evaluated for cytotoxicity, hemocompatibilty, and accuracy both using in vitro and in vivo methods. Continuous monitoring of blood glucose levels has been an elus ive goal, but would greatly improve the care for critically ill patients in managing insulin therapy. PUBLIC HEALTH RELEVANCE: The goal in this grant is to make an intravascular glucose sensor that measures blood glucose levels continuously for 7 days. By maintaining sensor function, this technology will provide health care professionals with immediate changes in patient health and decrease complications. Currently sudden changes in glucose levels are not detected leading to increased health care costs and increased risks to patients.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

68 SBIR/STTR records share this UEI (1991–2023). Reported award amounts total $29,918,691. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Defense

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.