SBIR/STTR Research Award

NOVEL PHOTOSENSOR FOR SCINTILLATION CAMERAS

Award identifier e212ac3021fe9661066236b52d495a021d78b03390a3152d847b3cabd51011cbAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$100,001

Program and phase

SBIR · Phase I

Award year

2002

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Photon Imaging, Inc.
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant):The use of Photomultiplier Tubes (PMTs) in the construction of gamma cameras for nuclear medicine has been largely unchanged since the 1950's. Recently there has been an intensive effort by several groups including ourselves to develop various types of solid state gamma cameras because they offer vast improvements in performance, size and weight, and cost. To date gamma cameras based on solid state detectors have not achieved all of these goals because of basic limitations of the solid-state detector technologies explored so far. The performance of solid-state photodetectors is limited by noise due to their capacitance and leakage current. We have made significant progress on the development of silicon drift photodetectors (SDPs) for direct replacement of the PMT's in Anger cameras. The main advantage of these new detectors is their extremely small capacitance (independent of detector size) and low noise. However until now these devices have needed a large amount of cooling (deltaT=50 degrees C). During the proposed Phase I effort we propose to investigate a significant innovation in drift detector design that adds internal gain to the drift detector. This mitigates leakage current noise so that the new devices do not have to be cooled. We propose to fabricate test structures showing the feasibility of the approach in Phase I and to finalize the technology during Phase II. This technology will result in vastly superior performance and low cost compared to other technologies such as APDs, PIN diodes, proposed as PMT replacements in the past. These novel devices will be assembled into a 20cm diameter prototype Anger camera during Phase II. PROPOSED COMMERCIAL APPLICATION: This technology has potential for replacement of photomultiplier tubes used in conjunction with scintillation crystals for gamma-ray spectroscopy, nuclear medical imaging, photon counting, etc. The overall market for the instrumentation in these areas is in the billions of dollars. The portion of this market addressed by this technology is in the hundreds of millions of dollars.

Technology keywords

Not reported

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.