SBIR/STTR Research Award

Rapid sensitive low-cost test for resistant microbes causing hospital infections

Award identifier 77d83470027a0d363c47af3bf906e57fb86978da0dd2d2461b1d94f41b552844Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$2,906,840

Program and phase

SBIR · Phase II

Award year

2011

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
FIRST LIGHT BIOSCIENCES, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
GSH1NF35LK69
Solicitation number
PA10-123
Topic code
NIAID

Research abstract

DESCRIPTION (provided by applicant): We propose to develop a novel automated platform to enable rapid, sensitive, user-friendly, and cost-effective screening for the antibiotic resistant bacteria that frequently cause serious healthcare associated infections. Every year, about 100,000 deaths result from 2 million serious healthcare associated infections at an estimated cost of 35B. About 20,000 fatalities are caused by the bacterium methicillin-resistant Staphylococcus aureus (MRSA). Many healthy individuals are colonized with MRSA. When these MRSA carriers are hospitalized, the resistant microbe can cause serious infections for the carrier and others in the hospital. Several recent studies have shown that hospitals can significantly decrease the number ofhealthcare associated infections by using rapid tests to screen admitted patients for MRSA colonization and then treating the colonized patient with rigorous infection control procedures. New rapid MRSA tests based on PCR are fast, but are either too expensive or too complex to be implemented in most hospitals. Traditional microbiological methods for screening patients for MRSA are inexpensive but are too slow (1-2 days) to most effectively lower infection rates. We recently completed a Phase I project demonstrating the feasibility of a novel, rapid, simple, and cost-effective method for MRSA screening that should for the first time allow any hospital to implement rapid testing for infection control. The platform technology uses low-cost non-magnified digital imaging to rapidly count individual fluorescently labeled S. aureus cells. The test determines whether a patient's sample contains MRSA by testing for S. aureus cells that can grow in antibiotic-containing media during a brief incubation. The rapid (3.3hr) Phase I MRSA test's analytical sensitivity is comparable to PCR tests (10 CFU/sample). When applied to clinical nasal samples (n=163), the test showed high clinical sensitivity (95%) and specificity (98%) comparable to the on-market PCR tests. We alsodesigned, developed, and integrated a fully functional automated bench top analyzer prototype and developed and manufactured a low-cost consumable prototype for the MultiPath MRSA test. Here we propose to build on our Phase I work to develop a prototype automated platform and MRSA test cartridge that can be used in subsequent Phase III beta field trials. Specifically we aim to (1) further decrease time to results and develop optimized stable reagents; (2) develop a low-cost MultiPath MRSA/SA test cartridge;(3) develop a low-cost automated beta MultiPath analyzer; (4) integrate and verify the platform functionality; and (5) demonstrate the performance of the MultiPath MRSA/S. aureus (MRSA/SA) test. Achieving these Specific Aims will enable subsequent Phase III beta field testing that will in turn support a future regulatory submission. The MultiPath platform will also be able to accommodate a broad menu of tests for agents that cause healthcare associated infections (e.g., vancomycin resistant Enterococcus and C. difficile), infectious viruses, food pathogens, toxins, molecular disease markers, and drug discovery targets.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

7 SBIR/STTR records share this UEI (2003–2021). Reported award amounts total $13,893,901. Reported amounts are not federal obligations.

Phases: Phase II, Phase I, Phase II – Direct to Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.