SBIR/STTR Research Award

High throughput cell-free ion channel screening workstation

Award identifier 958171a90d23117dca87c7a077f85341db1e86c5404a223ec397c76eacdfe1beAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,552,831

Program and phase

SBIR · Phase II

Award year

2012

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
LIBREDE
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
PA11-096
Topic code
NIGMS

Research abstract

DESCRIPTION (provided by applicant): Ion channels are important drug targets-present in every cell, they play key roles in a wide range of physiological processes including the cardiac cycle and neural activity. As a result, unintended drug interactions with ion channels are also of critical importance, requiring the screening of all drug candidates against specific ion channels. Unfortunately, assaying ion channels for pharmaceutical discovery and safety screening is problematic to perform in high throughput because the ion channels must be incorporated into a cell membrane to allow measurement of their ionic transport to determine their functionality. As a result, there are currently no high quality, high throughput assays for ion channel screening. Recentdevelopments of automated patch clamp instrumentation are still over an order of magnitude lower throughput than conventional drug screening for soluble proteins and also require expensive instrumentation, specialized cell lines, and consumables. For existing methods of ion channel screening, there is a large gap in information quality, throughput, and cost. Librede's goal is to develop new technologies that increase the efficiency of early stage pharmaceutical research and development. To this end, Librede is developing an alternative cell-free technology for ion channel screening using artificial cell membranes. Librede's patent pending formulation of cell-free artificial membranes can enable higher throughput and lower consumable costs while requiring less expensive equipment and trained personnel. Librede was founded by UCLA researchers and the inventors of this technology. In Phase I, we measured a 48 membrane array plate simultaneously with a multichannel amplifier and verified that the measurement performance was equal to or exceeded competitive automated patch clamp instruments. In the Phase II work proposed here, we will build on this work by integrating our Phase I instrumentation with fluid handling and motion control hardware to construct an automated workstation for cell-free ion channel screening using Librede's artificial membrane technology. We will consult with a pharmaceutical screening industry automation expert in the design, construction, and operation of our workstation and confirm that it can process and measure Librede's artificial membrane plates similarly to our previous work. To demonstrate its capabilities, we will perform a limited screen of CLIC1, an ion channel implicated in Alzheimer's disease. CLIC1 is particularly difficult toscreen with conventional patch clamp, which makes this an ideal proof-of-concept application of our platform. We will work with the Schmidt group at UCLA, who have previously demonstrated the measurement of CLIC1 in artificial membranes. We will run the workstation in full automation mode, measuring ion channel activity as a function of drug concentration for a 72 compound ion channel-targeted drug library. This demonstration is essentially identical to an industry screen and is a major milestone for Librede's development of our artificial membrane technology, which promises an order of magnitude improvement in cost and throughput for ion channel screening. PUBLIC HEALTH RELEVANCE: Librede is developing a novel cell-free ion channel screening platform that has the potential to significantly reduce costs and increase throughput of drug discovery and safety screening for ion channels. We will develop an ion channel measurement workstation that is capable of completely automated processing and measurement of Librede's ion channel plates after the addition of drug compounds modulating the channel activity. We are validating this workstation by screening compounds for activity against the CLIC1 human ion channel which is thought to play an important role in Alzheimer's disease.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.