SBIR/STTR Research Award

Automated Humand Fecal Polllution Detection

Award identifier bbe46678a141a0d923a12303b211775ee6f51ef20175e0fbc816de715a016e28Awarding agency Environmental Protection Agency

Award amount

$70,000

Program and phase

SBIR · Phase I

Award year

2005

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Environmental Protection Agency
Branch
Not reported
Recipient company
Saigene Corporation
Proposal award date
Not reported
Contract end date
Not reported
UEI
Not reported
Solicitation number
Not reported
Topic code
Not reported

Research abstract

Worldwide over two million childer die each year form eneric waterborne diseases caused by fecal pollution. Diseases such as typhoid feaver, cholera, and hepatitis A are all transmitted by fecal contaminated water. Consequently, public health departments have set strict standards for the quantity of coliform bacteria allowd in the water. These standards are, for drinking water less than 1 coliform per 100 ml of water, for unfiltered drinking water from watersheds 50/100 ml, in shellfish growing water 70/100 ml, and in swimkming water 200/200 ml. Coliforms represent a group of aerobiv, gram-negative, non-sporulating bacilli most of which are Escherichia coli. Most E. coli strains are not pathogenic but represent an indication of gecal contamination and therefore the possible presence of other more harmful fecal pathogens. Because of the requirement to detect very low levels of these bacteria (1 per 100 ml of water) rapid automated detection is very difficult. Culture techniques take 24 hours and the more rapid DNA amplification techniques require DNA purification and use of unstable enzyes and nucleotides and elaborate instrumentation, all of which are difficul and expesive to automate. In this program. we will develop an automated biosensor capable of detecting low levels of fecal microorganisms without the need for bactrial culture or DNA amplification techniques. The biosensor should be sensitive enough to detect fecal microorganisms at a level of one coliform cell per 100 ml of water within 30 minutes. The sensing element will be reusable to allow for long-term, unattended, cost-effective analysis. The sensor should also distinguish human from farm livestock sources of fecal pollution. The fianl product is envisioned as an automated buoy placed in drinking water inlet source, swimming waters, and shellfish or other aquaculture growing waters. The buoy will report fecal nicroorganism levels at set time intervals by remote telemetry communications. Sampling times may be remotely adjusted based on rainfall that can cause excessive runoff that might increase fecal pollution by overwhelming the handling capacity of sewage treatment facilities. A non-buoy based protable version of the instrument will also be developed. This protable instrument can be used to analyze water samples on-site. Backtracking bacterial levels to their source can then find the pont source of the pollution. Then site-specific remedial action can be implemented.

Technology keywords

Not reported

Agency intelligence

Environmental Protection Agency

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.