SBIR/STTR Research Award

Development of a wearable telemetry module and dual hormone infusion set for use

Award identifier b838d88cec9315ecb12f96f57229453a5f5057bbabd3d113a9a2b227f8a269b1Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$223,845

Program and phase

SBIR · Phase I

Award year

2013

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
ADVANCED MEDICAL ELECTRONICS CORP
Proposal award date
Not reported
Contract end date
Not reported
UEI
GJ1KBJPEZL52
Solicitation number
DK13-001
Topic code
NIDDK

Research abstract

DESCRIPTION (provided by applicant): Advanced Medical Electronics Corporation (AME) and the University of Minnesota propose to develop a new graphene based continuous glucose monitor with passive wireless readout capability and dissolvable / biocompatiblemetallization layers for use in close-loop glucose control applications. Diabetes is the seventh leading cause of death in America and is likely to be underreported as a cause of death due to increases in other health problems caused by diabetes. Studies in the United States and abroad have found that improved glycemic control benefits people with diabetes. In general, every percentage point drop in A1C blood test results, for example, from 8.0 to 7.0 percent, can reduce the risk of microvascular complications-eye, kidney, and nerve diseases-by 40 percent. Development of treatment for patients with type-1 diabetes mellitus (T1DM) has advanced considerably in the past several decades to the point where the realization of an artificial endocrine pancreas (AEP)system consisting of a closed-loop plasma glucose monitoring system combined with an insulin delivery mechanism is now within reach. However, significant challenges remain in obtaining reliable, cost-effect, patient-friendly glucose monitoring systems. Inthis work, we describe a fundamentally new method of sensing glucose that has the potential to overcome numerous limitations of current CGMs, particularly regarding their size, invasiveness and inconvenience to the patient. The sensor is novel, because itis based upon a little-appreciated property of graphene called the quantum capacitance effect. Graphene is a two-dimensional allotrope of carbon that has numerous unique and extraordinary properties. The quantum capacitance effect in graphene allows the capacitance in a suitably-configured device to change when the electron concentration in the graphene changes. This allows graphene to act as an extraordinarily sensitive variable capacitor (varactor) whose capacitance can be tuned in response to the presence of a particular biomolecule, depending upon how the graphene surface is functionalized. If combined with an inductor, this device allows the glucose concentration to be encoded as the frequency shift of a passive resonator circuit. This sensing method has the potential to overcome the numerous limitations of conventional GCMs, as well as provide unique capabilities that are ideally suited for use in closed-loop artificial pancreas systems. In phase I, the feasibility of creating a disposable version of this sensor will be investigated by fabricating sensors where the graphene surface has been modified to be sensitive to glucose. Separate varactor and inductor designs will be created in order develop an estimate of the final device sizes that are possible.The feasibility of creating devices using biocompatible, dissolvable metals, such as magnesium, will also be investigated. The circuitry for wireless readout will also be developed and tested. AME has assembled an excellent team to develop this sensor andreadout capabilities. In phase II, production prototype sensors and readout electronics will be built and tested on a patient population. PUBLIC HEALTH RELEVANCE PUBLIC HEALTH RELEVANCE: Continuous glucose monitors are a necessary component ofclosed-loop glucose control systems for treatment of diabetes mellitus. A simple, cost-effective wireless subcutaneous glucose sensing platform could provide enormous benefits for long-term diabetes mellitus patients utilizing closed-loop glucose control systems.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

138 SBIR/STTR records share this UEI (1994–2024). Reported award amounts total $61,745,451. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Health and Human Services, Department of Education, National Aeronautics and Space Administration, Department of Homeland Security, Department of Agriculture, National Science Foundation

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.