SBIR/STTR Research Award
A Cell-based Assay for Botulinum Neurotoxin Detection and Development
Award amount
$99,986Program and phase
SBIR · Phase IAward year
2013Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- Q-Track Corporation
- Proposal award date
- Not reported
- Contract end date
- Not reported
- UEI
- Not reported
- Solicitation number
- ES12-005
- Topic code
- NIEHS
Research abstract
DESCRIPTION (provided by applicant): The proposed effort aims to dramatically enhance the realism of radiation safety training for Emergency Responders, both First Responders, as well as Skilled Support Personnel. The goal is to develop andevaluate realistic dosimetry simulation or Dosimulation tools. These Realistic, Accurate Dosimulation (RAD) tools will be the centerpiece for an effective Emergency Responder radiation training curriculum. This Dosimulation concept employs a Real-Time Location System (RTLS) integrated with realistic simulated dosimeters. A sophisticated software algorithm generates a Virtual Radiation Environment (VRE), assigning a particular dose rate to every location within the training area. Dosimulation merges the real-time location of the trainee from the RTLS with the simulated dose rate from the VRE to yield a realistic radiation dose simulation. he proposed Advanced Technology Training (ATT) provides a Virtual Reality simulation of any radiological emergency in a particular training environment. In the proposed RAD effort, the investigators will implement a dynamic and time varying VRE to model the evolution of plumes and spills of interestto Emergency Responders. In addition, they wil work with Radiation Safety and Control Services, Inc. (RSCS), leaders in training Emergency Responders, to select appropriate radiation instrumentation and scenarios to emulate. The impact ofthe proposed RAD system, if successful, will be to transform emergency responder training with realistic and accurate hands-on radiation simulations that will enable Emergency Responders to practice like they play. The commercial potential is similarly compelling. Q-Track is already a leading vendor of radiation dosimetry simulation products for the nuclear power industry. The substantial improvements in Dosimulation systems made possible by the proposed RAD effort would enable Q-Track to serve the Emergency Responder training market as well. PUBLIC HEALTH RELEVANCE PUBLIC HEALTH RELEVANCE: Q-Track proposes to dramatically improve the realism of radiation safety training for Emergency Responders, (both First Responders, as well as Skilled Support Personnel) by employing a Real-Time Location System in conjunction with a time varying Virtual Radiation Environment to create a high-fidelity Virtual Reaity radiation simulation. The proposedRealistic Accurate Dosimulation (RAD) project has the potential to enhance radiation training and thus reduce Emergency Responder radiation exposure.
Technology keywords
Not reported
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
- Bioinspired Green Glycolipids as Fugitive Dust Mitigation Agents
- Supercritical Fluid Cartridges for Calibration of Air Pollution Sensors
- Weight Loss and Endocrine Disrupting Chemicals (EDCs): Lifestyle interventions to lose weight and reduce EDC exposure in individuals with overweight/obesity
- High-Resolution Ground-Level AQ Monitoring System Using Hyper-local Low-cost Sensor Nodes and AI Forecasting
- Bringing PFAS Monitoring Home: An Integrated Magnetic Nanoparticle and Lateral Flow Assay System