SBIR/STTR Research Award

Silicone-free glass pre-filled syringe system for Biological Drugs.

Award identifier a18d69bf7d4d7d88470b57b0484458bc4916a5b56d7e884b062149f12d543c31Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$229,475

Program and phase

SBIR · Phase I

Award year

2009

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
TRIBOFILM RESEARCH INC
Proposal award date
Not reported
Contract end date
Not reported
UEI
UFJ5KEMVE414
Solicitation number
PHS2009-2
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): In the medical device industry, silicone oil is a ubiquitous lubricant - used in the manufacture and assembly of components and also as the terminal lubricant for proper device operation. For prefilled syringes, the problem arises when micro-droplets of silicone oil migrate into the drug medium and act as a contaminant and possible reactant for the packaged drug. In the case of biological drugs, such silicone oil contamination has been implicated in protein conformational changes and aggregation. Glass syringes for prefilled applications predominantly use silicone oil as a lubricant. A silicone oil-free glass prefilled device is highly desired, but before it would be accepted, stability testing with various pharmaceutical ingredients as well as particulate and force testing after extended storage is required. We propose the development of glass prefilled syringes with the TriboGlide(r) silicone-free lubrication system based on perfluoropolyether chemistry. The effect of accelerated storage conditions on break-loose and extrusion syringe forces along with comparison of the particulate generation between standard silicone oil lubricated and TriboGlide(r) silicone-free syringes is proposed. In collaboration with the University of Colorado Denver, UCD, TriboGlide(r) syringes will be compared to standard siliconized syringes as devices for packaging of protein formulations. Protein precipitation (UV/Vis spectroscopy), loss of soluble protein (SE-HPLC), influence of adsorbed protein on syringe forces, and pH shifts in water for injection will be assessed. The proteins selected for this study are human serum albumin, human IgG, insulin, and abatecept (monoclonal antibody by Bristol Myers Squibb). In phase II, we propose to evaluate the TriboGlide(r) glass syringes for effects on secondary and tertiary structural changes of the proteins, using circular dichroism and fluorescence spectroscopy. Differential scanning calorimetry will be used to detect changes in the thermodynamic stability of the proteins after extended storage in the syringes. Finally, with the extensive experience in vaccines brought by Dr. LaToya Jones Braun from UCD, we will evaluate the stability of various vaccine formulations stored in the syringes. The medical device and pharmaceutical industries have long desired a completely silicone-free system that does not affect the stability of the packaged drug in solution. If successful, TriboGlide will be the first universal silicone-free system for glass prefilled syringes with applications extending to other medical devices. PUBLIC HEALTH RELEVANCE: Patient controlled self-therapy is a big driving factor for drugs packaged in single-dose prefilled syringe formats for treatment of chronic ailments such as rheumatoid arthritis and diabetes. Other advantages include reduced errors, ease of use, accurate dosage, elimination of preservatives in case of multi-dose vaccines and above all reduced overfill of drugs that are required for packaging in vials. Silicone oil, which serves as a lubricant for easy operation of the syringe, can contaminate the drug product and adversely interact with the sensitive drugs. The proposed TriboGlide system will be the first silicone oil-free system for glass prefilled syringes that overcomes the problems of lubricant migration and drug contamination.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

11 SBIR/STTR records share this UEI (2000–2018). Reported award amounts total $6,903,751. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.