SBIR/STTR Research Award

End of Life Service Indicator

Award identifier 931dedb12ec7473b5c899fb1cc9a5eb2188b3b18c7086a9445ed61ccbd8c9b3dAwarding agency Department of Health and Human Services · Centers for Disease Control and Prevention

Award amount

$100,000

Program and phase

SBIR · Phase I

Award year

2009

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
Centers for Disease Control and Prevention
Recipient company
TDA RESEARCH, INC.
Proposal award date
Not reported
Contract end date
Not reported
UEI
MK5ANJVWVZK7
Solicitation number
Not reported
Topic code
Not reported

Research abstract

DESCRIPTION (provided by applicant): First responders and chemical workers must be able to function in environments where chemical hazards are present. Industrial workers need protection against hazardous chemicals used in the workplace and HAZMAT personne l need respiratory protection when dealing with chemical spills, methamphetamine labs, and other cleanup operations. In the event of exposure to chemical vapors/gases from an industrial or environmental accident, respiratory protection is particularly impo rtant. The modern gas mask has a vapor tight polymer face piece that is equipped with windows and a cartridge containing activated carbon that filters the inhaled air. Most modern masks have a check valve so that exhaled air passes out of the valve rather than back through the activated carbon cartridge. As air is inhaled through the activated carbon in the cartridge, hazardous contaminants physically adsorb on the carbon surface, and because activated carbons can have surface areas of 1000 m2/g or greater, reasonably large amounts of contaminants can be removed with a single cartridge. To date, no simple technology has been developed that allows the user to determine if the chemical protection capability of a respirator cartridge has been reduced by exposur e during storage, or by saturation with gases while it is in use. What is needed is a simple device that indicates the expiration of a respirator cartridge. This device would be a permanent part of a respirator cartridge integrated into the cartridge durin g manufacturing. Since the device is incorporated into the respirator cartridge during manufacture, the indicating device can be certified by NIOSH, and thus used by first responders. TDA proposes to develop an end of service life indicator (ESLI) that can be incorporated into a first responder chemical hazard respirator cartridge. PUBLIC HEALTH RELEVANCE: There is no simple technology has been developed that allows the first responder to determine if the chemical protection capability of a respirator cartr idge has been reduced by exposure during storage, or by saturation with gases while it is in use. What is needed is a simple device that indicates the expiration of a respirator cartridge. This device would be a permanent part of a respirator cartridge int egrated into the cartridge during manufacturing. Since the device is incorporated into the respirator cartridge during manufacture, the indicating device can be certified by NIOSH, and thus used by first responders. TDA proposes to develop an end of servic e life indicator (ESLI) that can be incorporated into a first responder chemical hazard respirator cartridge. In order to accomplish these goals in the proposed Phase I project, TDA proposes to build a test apparatus that permits us to generate precise and verifiable concentrations of challenge agents for testing the indicator, prepare indicator test strips on a porous support material, test indicator sensitivity using a variety of challenge vapors at different concentrations, temperatures, and relative hum idities, in collaboration with our manufacturing partner, construct and test a prototype device, and perform an engineering analysis to estimate the costs of manufacturing commercial units.

Technology keywords

Not reported

Research funding history

951 SBIR/STTR records share this UEI (1988–2026). Reported award amounts total $317,960,224. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Defense, Department of Energy, National Aeronautics and Space Administration, Environmental Protection Agency, National Science Foundation, Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.