SBIR/STTR Research Award

Breath aerosol capture by electric field concentration

Award identifier 7f291f12f420f8c43bd53786ba8fa119b0a82ac2bdaf7e33f9f9321de212a865Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$293,968

Program and phase

SBIR · Phase I

Award year

2024

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
VOX BIOMEDICAL LLC
Proposal award date
2024-08-15
Contract end date
2025-07-31
UEI
FNQYUK4GTB29
Solicitation number
PA23-230
Topic code
NIDA

Research abstract

Project Summary This proposed project is aimed at developing a method for capturing and concentrating exhaled breath aerosols by electrostatically charging them and collecting them on sub-mm diameter areas for optimal trace aerosol detection sensitivity by infrared tunable laser spectroscopy (TLS). An immediate application for this technology is detection of trace amounts of the marijuana intoxicating aerosol ingredient tetrahydrocannabinol (THC), but other applications include detection of dangerous drugs and viruses. Prior work on spectroscopic sensing of THC at Vox Biomedical indicated that exhaled breath aerosol area concentration is needed because the sub-ng amounts of THC in exhaled breath aerosols are so small that the captured aerosols do not entirely cover the 1 cm2 sample areas typically used in infrared spectroscopy, thereby reducing system sensitivity. Modeling showed that aerosol concentration onto sub-mm diameter areas of diameter equal to the diffraction-limited focused TLS quantum cascade laser spot size enables optimal detection sensitivity, resulting in several orders of magnitude improved spectroscopic detection sensitivity because a much larger fraction of the focused probe laser light will be absorbed by the concentrated analyte. The required sub-mm diameter area THC aerosol analyte concentration will be achieved by electrostatically charging the exhaled breath THC aerosols and then accelerating the charged aerosols onto an electrically conducting silicon coupon covered with a non-conducting oxide layer into which a 0.1 mm diameter opening is photolithographically defined. This photolithographic wafer fabrication process will be carried out in a local semiconductor foundry. The design of the patterned silicon wafer will be such that the wafer can be sectioned into identical small coupons, each with a single 0.1 mm diameter oxide opening, that will then be used in the planned analyte deposition experiments. To demonstrate the efficacy of this proposed new aerosol concentration method during Phase I Vox Biomedical will first use a well-characterized Alphazurine-A dye obtained from a nebulizer and precision injected into a polycarbonate cylinder and charged by an electric field of several kV/cm as created by a cylindrically symmetric arrangement of three tungsten tip corona needles. Since the Alphazurine-A dye is well characterized by its known spectral absorption characteristics, it will be possible to determine the minimum detectible amounts of deposited dye aerosols. Following the Phase I Alphazurine-A dye concentration study, a more refined feasibility demonstration will be carried out using THC aerosols that will be generated by nebulizing methanol with quantitatively known THC concentrations obtained from commercial THC-in-methanol solutions. Phase II will then include human marijuana user exhaled breath measurements. Successful development of the proposed new electrostatic aerosol concentration method will provide both law enforcement and employee screening personnel with a non-invasive means for identifying marijuana and drug users in real time. If successful, this aerosol capture technique could also be applied to identifying exhaled breath virus content.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

5 SBIR/STTR records share this UEI (2019–2024). Reported award amounts total $3,114,933. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, Department of Transportation

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.