SBIR/STTR Research Award

DoseRT™ : A Non-Contact Optical Patient and Beam Dosimetry System for Continuous in vivo Radiotherapy Verification

Award identifier dcd520eb3db10ebfc40e5faac4c81d23668267378bc46b99d1fbdf52f0291c2aAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,997,948

Program and phase

SBIR · Phase II

Award year

2024

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
DOSEOPTICS LLC
Proposal award date
2024-06-13
Contract end date
2027-05-31
UEI
QERKPUEMGKH3
Solicitation number
CA23-034
Topic code
102

Research abstract

ABSTRACT Radiation therapy (RT) is a curative treatment, used adjuvant to surgery and chemotherapy in over 60% of cancers. It is delivered to nearly 1 out of every 6 people at some point in their lifetime. External beam treatment is commonly fractionated (i.e., delivered in 25-40 daily fractions), although there is a trend towards hypofractionation (5-10 days) with higher doses per fraction. While RT is generally considered safe and effective, it is well known that minor deviations in treatment happen on a daily basis in a busy treatment facility, and these changes are prone to higher human error rates. Major potential side effects can occur if not administered with high daily accuracy, and the precision needed is at the millimeter level in patient and beam alignment, in order to keep normal tissue doses sufficiently low. However, there is a proven 1-5% incidence of secondary cancer from this treatment. This is particularly relevant in whole breast radiotherapy, where even 2% target dose delivery (1Gy) to part of the contralateral breast has been proven to lead to a high probability for a secondary cancer. In reality, no clinic actually knows their true incident rate, because no system exists to visualize every treatment as part of routine clinical practice. DoseOptics’ invention of Cherenkov imaging, branded as BeamSite™, provides time-gated single photon video rate imaging of the light coming off tissue during the radiation dose delivery as it happens. The parent Phase II grant for this proposal, funded development of Cherenkov imaging with the VisionRT surface guided radiotherapy system (SGRT) system. Together the combined system has been trademarked as DoseRTTM, where the Cherenkov video of dose delivery is displayed in the same window monitor as the SGRT metrics of patient position. This combined interface provides a complete intuitive package for the therapists, where daily assessment and corrections can be made as needed. VisionRT and DoseOptics have a signed a long-term partnership and license and finance agreement. In this Phase IIB application, key improvements are implemented from test use, to make DoseRT more commercially viable for widespread deployment across different vendor platforms, more easily used by various therapy teams, and with some customization approaches for each center. The project is based upon previous NIH supported hardware that is now FDA 510(k) cleared. Aims 1 & 2 advance strategic updates to hardware and software systems for which improve cost structure and robustness, improving commercial viability of the system. This updated system will also be 510(k) cleared in Aim 3 with beta deployment. The project will culminate in Aim 4 with broader deployment and testing validation with an image registry. This clinical registry data will be used to validate marketing claims around incident detection and improved radiotherapy delivery by visualization of the beam on the patient. The team involved encompasses the two companies with expertise across all areas of development, as well as a number of clinical partner sites. The company has secured third-party investment for the Phase IIB matching funds. This project will complete commercialization readiness of DoseRT for a customer-ready solution.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

13 SBIR/STTR records share this UEI (2015–2025). Reported award amounts total $14,999,062. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.