SBIR/STTR Research Award

Feasibility, Pilot, and Communication studies towards Translation of Aurie Reusable Catheter System into Clinical Practice.

Award identifier d0285e654046f9350ec8646a98a043b7f1c186a8c026806638350317bb643950Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$404,988

Program and phase

SBIR · Phase II

Award year

2024

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
CATHBUDDY INC
Proposal award date
2024-05-15
Contract end date
2025-04-30
UEI
JJK1MMTLKBS7
Solicitation number
PA23-231
Topic code
400

Research abstract

Enter the text here that is the new abstract information for your application. This section must be no longer than 30 lines of text. 600,000 people in the US rely on intermittent catheterization (IC) for bladder emptying, but current IC products not adequately meet users’ needs. CathBuddy, Inc. has developed a novel IC system that is safely reusable, with an automated, validated method to clean, disinfect and lubricate catheters for re-use. The objective of this SBIR Phase II project is to modify the design of the 16” Aurie Reusable Catheter System (developed first due to increased technical difficulty and use by both male and female IC users) to a 6” system (preferable for many female IC users and needed to enhance widespread appeal and recruitment for clinical studies). Patients with neurogenic bladder (NB) are often unable to void spontaneously and require self-administered IC multiple times each day. Current guidelines recommend the use of a new single-use catheter with each catheterization, a practice adopted to reduce infection risk, although IC still contributes to a 50% annual complicated urinary tract infection risk. No-touch catheters reduce this infection risk by 44.5% with features including introducer tips and insertion sleeves that reduce the likelihood of contact contamination, but they are often prohibitively expensive on a per-use basis and only 5% of the user population can access them. These factors have led to CathBuddy, Inc.’s development of a safely reusable no-touch urinary catheterization system that alleviates many of the documented obstacles in IC with a specific focus on human factors and ease-of-use through a no-touch design. By incorporating a personal portable washer-disinfecting carrying case for use by the individual into this novel catheterization system, the notouch catheters can be safely reused on-the-go, and per-use costs drop dramatically. In addition, plastic waste from catheterization can be reduced by up to 85%. In this Phase II project, 1) the existing 16” system will be modified to incorporate 6” catheterspecific design requirements. Modification of the 16” system will require first evaluating the decrease in fluid volume requirements between the two catheter lengths; this will be translated into smaller supply needs, smaller batteries (for onboard pumps), and a smaller overall footprint. This effort will culminate in the development of an alpha prototype of the female system that can be used in future efforts for FDArequired Verification and Validation testing.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

5 SBIR/STTR records share this UEI (2020–2024). Reported award amounts total $2,335,988. Reported amounts are not federal obligations.

Phases: Phase II, Phase I

Agencies: Department of Health and Human Services, National Science Foundation

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.