SBIR/STTR Research Award

Multi-detector Array CD-MS for Rapid Analysis of Very High Mass Analytes

Award identifier 2ce2f8bb8d620bb15c94d9c595994d60f6959f8b82f16d507230c868626a3fe0Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$294,200

Program and phase

SBIR · Phase I

Award year

2024

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Megadalton Solutions Inc
Proposal award date
2024-05-01
Contract end date
2024-10-31
UEI
YLV3TGEMNQY5
Solicitation number
PA23-230
Topic code
400

Research abstract

Project Summary/Abstract This proposal describes key steps towards designing a high-throughput charge detection mass spectrometer that is optimized for very high mass particles in the megadalton and gigadalton mass range. Charge detection mass spectrometry (CD-MS) is an emerging technology capable of accurately measuring the mass of large and heterogeneous analytes, making it highly suitable for a wide array of applications including biopharmaceuticals including gene therapy vectors, virus particles such as adenovirus and lentivirus, liposomes, and large miomarkers such as lipoproteins and exosomes. CD-MS often employs an electrostatic ion trap containing a conductive detection cylinder connected to a charge sensitive amplifier. Trapped ions repeatedly pass through the detection cylinder, generating a square wave signal, and are individually analyzed by Fast Fourier Transform for their mass-to-charge ratio (m/z) and charge by measuring their oscillation frequency and signal magnitude, respectively. While a trap offers the highest charge resolution, and therefore the highest mass resolution, it suffers from low sensitivity and can be time-consuming. For example, routine mass spectrum acquisition takes around 15 minutes for a sample with 1012 particles/mL and the lower detection limit is approximately 1010 particles/mL. Lower concentrations also require longer to analyze. In this proposal we aim to design a detector array CD-MS instrument capable of enhancing the sensitivity and throughput by two orders of magnitude for heterogeneous samples where higher mass resolution is not necessary for accurately characterizing the mass distribution. This array will consist of ten individual detection cylinders in a linear arrangement. Ions will be flown through the array and refocused towards the central axis by electrostatic lenses. Charge sensitive amplifiers and analog to digital converters will generate and send signals from each detector to a central processing unit such as a field-programmable gate array (FPGA) for the signals to be packaged into files and then sent to a server for data processing. In this investigation, development will begin by performing ion trajectory simulations for optimizing geometric parameters of the array and focusing voltages applied to the lenses to maximize ion transmission through the array, thereby maximizing sensitivity. These trajectories will then be used to generate representative simulated signals. Following from that, code will be written to extract the ion m/z and charge from the simulated signals. Alongside code development, we will explore different amplifier configurations that give rise to the fastest analysis and best charge determination. Finally, we wish to develop an integrated circuit for CD-MS amplifiers which has the potential to significantly improve the charge measurement precision and will have a more robust and reproducible construction than the current custom amplifier design. The development of this high-throughput CD-MS array is key to meeting the need for an instrument capable of accurately and rapidly characterizing the mass distribution of very heavy biological analytes.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

3 SBIR/STTR records share this UEI (2019–2024). Reported award amounts total $1,631,908. Reported amounts are not federal obligations.

Phases: Phase I, Phase II – Direct to Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.