SBIR/STTR Research Award

Autonomous Monitor for Toxic Gas Exposure

Award identifier 9b334786bbf5235382aa1e8a8e5a20588ce0002461b544cb0f3d0bb23ea94a67Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,838,436

Program and phase

SBIR · Phase II

Award year

2024

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
ZEBRA ANALYTIX, INC.
Proposal award date
2024-04-15
Contract end date
2026-03-31
UEI
RUFNC8965Z83
Solicitation number
PA22-176
Topic code
R

Research abstract

Project Summary The overall goal of this SBIR project is to develop a miniature, microfabricated gas chromatography (micro GC) device for autonomous, near real-time monitoring of toxic VOCs (volatile organic compounds) in the workplace. A key differentiator is exploring a low-cost multilayer fabrication process to develop a new-type micro GC. Through the Phase I project, a working prototype of the proposed micro GC has been created and has demonstrated rapid and sensitive measurement of representative toxic VOCs in air. This Phase II study will further optimize the designs and fabrication of key micro GC components developed in Phase I and create a commercial prototype. Micro GC method development and validation for additional toxic VOCs, as well as pilot testing, will also be pursued in Phase II. The final product will be a plug- and-play toxic VOC monitor with online sampling and onboard calibration capabilities. Toxic or even carcinogenic VOCs can be emitted into the workplace and environment from many industrial and chemical processes, posing a serious health hazard to workers as well as the general public. Therefore, there is a critical need for sensitive and accurate monitoring of VOC exposure in real time or near real time. Unfortunately, existing approaches are associated with major limitations due to the lack of specificity (e.g., colorimetric detection tubes and photoionization sensors), or because of the requirement of a bulky/expensive instrument or offline sampling (e.g., traditional GC methods). The proposed micro GC aims to overcome these drawbacks and address the critical needed for autonomous, continuous, and specific monitoring of VOC exposure.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

5 SBIR/STTR records share this UEI (2019–2024). Reported award amounts total $2,769,142. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, National Science Foundation

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.