SBIR/STTR Research Award

Automated microfluidic device for blood analysis in neonates

Award identifier af8ecd2f873cd5f19dbb231af0af082bda6bbdded0b4ba2c1b6d7c001843351eAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,554,926

Program and phase

STTR · Phase II

Award year

2024

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Sersense Inc
Proposal award date
2024-03-01
Contract end date
2026-04-30
UEI
CANSDRLH1FD7
Solicitation number
PA22-178
Topic code
NICHD

Research abstract

ABSTRACT Premature infants are frequently at risk of infections, jaundice and hypoglycemia – conditions monitored by analysis of blood for c-reactive protein (CRP), bilirubin and glucose respectively. Typically, 0.5 mL of blood is drawn each time an infant is tested, with multiple blood draws happening over the course of days. Given that a total blood volume for premature infants may be as little as 50 mL, up to 20% of blood volume may be lost due to testing. This puts infants at risk of iatrogenic anemia and packed red blood cell transfusions. While these transfusions are considered safe in many regards, they do expose neonates to transfusion-acquired infections, cytomegalovirus in particular. Our team has identified a need for a volume-sparing blood analysis platform that could be deployed in neonatal intensive care units (NICUs). During Phase I of this STTR application, we de- veloped a valve-enabled microfluidic device capable of isolating plasma and analyzing multiple biomarkers, including glucose, from ~5 microliters of blood in under 10 min. Our device used ~100 fold less blood and de- livered results 10 times faster compared to current assays while eliminating the need for benchtop laboratory equipment (e.g. centrifuge for plasma separation). The microfluidic devices were prototyped in silicone rubber (PDMS). During Phase II of the project, we will fabricate automated microfluidic devices using materials ame- nable to scalable and inexpensive manufacturing. Our devices will be capable of detecting CRP, bilirubin and glucose and will be suitable for operation at the point of care, in the NICU. Broader impacts: The microfluidic device and control system to be developed in this project represent a plat- form technology with broad utility for monitoring a wide range of analytes from a small blood volume. This means that, in the future, the multiplexing capabilities of this technology may be enhanced to incorporate other analytes relevant to neonatal health including but not limited to inflammatory cytokines for detection of sepsis, potassium ions, calcium ions, and BUN.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

5 SBIR/STTR records share this UEI (2015–2024). Reported award amounts total $3,788,458. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, National Science Foundation

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.