SBIR/STTR Research Award

PREFAB MODULAR LIQUID-COOLED MICRO DATA CENTER

Award identifier e59d27a943c91c206d6c48de5949fc1cd87a2b6ff1b443a0d87d56527c6db8cdAwarding agency Department of Energy · ARPA-E

Award amount

$306,808

Program and phase

STTR · Phase I

Award year

2023

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Energy
Branch
ARPA-E
Recipient company
FLEXNODE INC
Proposal award date
2024-01-23
Contract end date
2027-01-22
UEI
D9J5JJ3BLBJ1
Solicitation number
Not reported
Topic code
1

Research abstract

"To enable the future needs of efficient computing for edge data centers, Flexnode and its partners, the University of Maryland (UMD), Boeing, Iceotope, SHoP Architects, and Arup, propose to develop a prefabricated modular micro data center with unprecedented energy efficiency and power density. The proposed system leverages four key component and system-level technology advancements: (a) a novel, experimentally proven, manifold microchannel heat sink technology that gives about three times higher heat removal rates at comparable pressure drops compared to the state-of-the-art technologies; (b) a chassis-based novel hybrid immersion cooling approach; (c) a low-cost, high-performance additive manufacturing-enabled dry cooling technology; and (d) a topology optimized container housing the entire system. These advancements will be achieved while meeting or exceeding the required performance, power density, cost, and sustainability metrics. The climate- and location-agnostic system will deliver a minimum power density of 20 kW/m3 within the volume of an ISO 40 shipping container. The total power consumption by heat rejection infrastructure and ancillary loads from the data center enclosure will not exceed 5% of the IT load. Sustainable design parameters include zero net water consumption, zero global warming potential (GWP), and zero ozone depletion potential (ODP) for all heat transfer fluids utilized. Deployment will be achievable shortly after delivery, only requiring an external power source and connectivity. System reliability will be engineered for at least 99.982% uptime. The proposed design will be cost-competitive with current state-of-the-art economic performance, including total system payback of under five years and a total system internal rate of return (IRR) of minimum 11%. Reliability will be optimized by leveraging reliability system engineering expertise currently in use in the data center, electronics manufacturing, and aerospace sectors. The Flexnode team comprises members with track records of success at marketing technological innovations and driving industry change, particularly in liquid cooling of electronic components, heat transfer, and modular prefabrication. Their expertise will be applied to the commercialization of the COOLERCHIPS modular micro data center."

Technology keywords

Not reported

Agency intelligence

Department of Energy

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.