SBIR/STTR Research Award

SBIR Phase I: Liquid Helium Transmission Electron Microscopy (TEM) Sample Holder for Atomic Imaging of Next-Generation Materials

Award identifier 97ec8de3009f403730f0a5158cbd556e7e67f46222b0bd1144fbea3d4c131a0bAwarding agency National Science Foundation

Award amount

$274,771

Program and phase

SBIR · Phase I

Award year

2024

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
National Science Foundation
Branch
Not reported
Recipient company
H-BAR INSTRUMENTS, LLC
Proposal award date
2023-12-01
Contract end date
2025-02-28
UEI
SFF3XNLU8VA4
Solicitation number
NSF 23-515
Topic code
IH

Research abstract

This Small Business Innovation Research Phase I project aims to enable atomic- and nano-scale imaging of materials and devices at temperatures as low as 10 K through the development of a stable liquid helium transmission electron microscope (TEM) specimen holder. Though TEM imaging modalities are amongst the most powerful metrology tools used in materials science, a long-standing lack of stable ultra-low temperature capabilities limits the range of their application to materials and technologies that operate at relatively high temperatures. Stable ultra-low-temperature capabilities are urgently needed for state-of-the-art TEM machines to enable scientific discovery and development across a broad range of emerging, previously inaccessible fields. This project targets and expands the electron microscopy market (expected to exceed $10 billion by 2028) which is rapidly growing in tandem with metrology needs of semiconductor, quantum device, renewable energy, and life-sciences markets. This project includes the development and testing of a novel cryogenic specimen holder with high stability as well as the quantification of high-resolution TEM imaging and stability metrics at liquid helium temperatures. To successfully gather atomic resolution or high-quality spectroscopic data, high thermal and vibrational stability, long hold times, and precise temperature control are necessary. Current low-temperature holders are not only incapable of reaching cold enough temperatures, but they suffer from significant instabilities and thermal losses, heavily affecting image resolution. They rely on small cryogenic dewars which lead to severe temperature fluctuations and vibrations as the unstable cryogen (liquid helium) rapidly evaporates. This project incorporates an innovative design with controlled liquid helium flow cooling, vibration decoupling, and precise temperature regulation over long hold times. The technology will result in the development of a commercial instrument that turns any TEM into an ultra-low-temperature imaging platform capable of characterizing novel materials for next-generation technologies. This award reflects NSF's statutory mission and has been deemed worthy of support through evaluation using the Foundation's intellectual merit and broader impacts review criteria.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Research funding history

2 SBIR/STTR records share this UEI (2024–2025). Reported award amounts total $1,524,770. Reported amounts are not federal obligations.

Phases: Phase II, Phase I

Agencies: National Science Foundation

Agency intelligence

National Science Foundation

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.