SBIR/STTR Research Award
Tissue Oxygen Scanning for Acute Compartment Syndrome (ACS) Diagnosis
Award amount
$276,073Program and phase
SBIR · Phase IAward year
2023Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- ASCAN LLC
- Proposal award date
- 2023-06-01
- Contract end date
- 2024-05-31
- UEI
- J3WMAD5X9MA6
- Solicitation number
- PA22-176
- Topic code
- NIAMS
Research abstract
PROJECT SUMMARY
Acute compartment syndrome (ACS) is a complication of extremity injury caused by increasingly elevated
intracompartmental pressure (ICP) that eventually compromises perfusion, causing ischemia of the muscles
within the compartment. If this persists longer than 6-8 hours, permanent ischemic damage to the muscle occurs
(myofibrosis and ischemic contracture). ACS demands immediate surgical fasciotomy to restore tissue perfusion,
yet early ACS diagnosis is problematic because of the current lack of a reliable diagnostic standard. Surgeons
rely on clinical judgment and index of suspicion to diagnose and make treatment decisions. Since delayed
fasciotomy is the most important factor contributing to poor outcomes; treatment decisions are biased towards
early intervention, often leading to unnecessary fasciotomy procedures. Since clinical findings are subjective,
measurement of ICP is commonly used despite lack of consensus regarding a threshold for performing
fasciotomy Research is needed to identify new methods to diagnose ACS.
ICP is the most common objective test used to diagnose ACS, but ICP does not tell the clinician whether the
involved muscles are healthy, ischemic, or necrotic, and has poor diagnostic specificity. Current ICP devices
provide only a single-point pressure measurement, although it has been shown that ICP varies throughout the
compartment. Furthermore, measurement of pressure via a percutaneous needle is subject to sampling and
technical error. These factors contribute to uncertainty about the ICP reading and therefore the diagnosis.
Here we propose developing a new method to diagnose ACS by measuring a depth profile of tissue oxygen in
the affected muscle. A-Scan LLC (Minneapolis, MN) has developed an optical scanning needle probe that scans
pO2 along its length without mechanical movement. In this project we will characterize the device performance
and then test it in a swine model that replicates the pathophysiology of ACS.
Commercially, the market of ACS diagnosis is derived from the fact that ACS is considered in every case of tibia
fracture. Considering an annual incidence of 300,000 tibia fractures in the US, the market is estimated at $90
million. This phase I of the project plan will focus on validating the functionality and performance of the probe in
a large animal model. In a future phase II extension we plan to significantly advance the process of
commercializing the device. It includes optimizing the device design for clinical application, perform testing and
device characterization for complying with FDA regulatory requirements and complete an initial request for
information (Q-Submission) to the FDA in order to obtain a specific device classification code and a pathway to
marketing clearance.
Technology keywords
Not reported
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
- Smart Cavity Creator Drill for Lumbar Interbody Fusion: Direct to Phase II
- Use of HIF-1alpha mRNA to Promote Pedicle Flap Healing.
- Development of novel genetic medicine approaches to treat orphan diseases
- A novel agent for preventing fatty degeneration of muscles in LGMD2B
- Bispecific biologic for rheumatoid arthritis therapy