SBIR/STTR Research Award

Fluorescence-Solid Phase Extraction (F-SPE) Platform for Rapid, On-site Detection of PFAS

Award identifier 195569fe5ae606d6037c12b608a45478c86321219b8b01098208d9c468de64b1Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$276,312

Program and phase

SBIR · Phase I

Award year

2023

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Espira, Inc.
Proposal award date
2023-05-16
Contract end date
2024-04-30
UEI
FEFCTPLYCPJ6
Solicitation number
PA22-176
Topic code
NIEHS

Research abstract

Project Summary Per-and polyfluoroalkyl substances (PFAS) have become an emerging class of water pollutants that cause serious environmental and health concerns. Due to their wide use in industry, military, and fire protection, PFAS have been spread and present in all kinds of water bodies. Among the over thousand PFAS ever manufactured and used, perfluorooctanesulfonic (PFOS) and perfluorooctanoic acid (PFOA) represent the top two PFAS used and studied the most for health effects. Recent studies indicate a tight linkage between exposure to these PFAS and many kinds of diseases and health effects. Currently, the advisory level set by the US EPA set for PFOS and PFOA in drinking water is 70 ppt (0.14 and 0.17 nM for PFOS and PFOA). Current detection of PFAS is mostly based on liquid chromatography coupled with mass spectrometry (LC-MS). However, the costs, footprint, power requirements, and sample preparation processes often associated with the LC-MS technologies limit their deployment beyond the formal laboratory setting. Especially for the detection of nanomolar levels of PFAS, LC-MS usually requires a preconcentration frontend device, making the analysis even more time-consuming. It becomes imperative to develop a rapid, simple, and low-cost sensor technology that is more suited for quick onsite detection of PFAS. While many chemical sensors, such as those based on fluorescence modulation, have been developed for the detection of PFAS, most of them are still far from sufficient for potable water analysis regarding either sensitivity (vs. 70 ppt) or selectivity (against the common chemicals, especially detergents). This project aims to fill this technical gap by developing a unique sensor platform that is small and easy to use, offering sensitive and selective infield detection of PFOS and PFOA (selected as the representative PFAS analytes). The sensor platform is based on highly sensitive and selective fluorescence sensors coated onto solid-phase extraction (SPE) capable of preconcentration of low concentrations of analyses, thus lowering the detection limit. The combination of preconcentration of SPE and fluorescence detection in one platform (namely F-SPE) would significantly simplify and speed up the analysis process. Moreover, F-SPE takes the principle of negligible depletion (ND) intrinsic to SPE, which would further simplify the analysis process by eliminating the need to precisely meter the sample volume as typically required for conventional analytical methods. ND relies on passing the minimal amount of sample through the membrane that is required for the analyte extraction to reach equilibrium. At this point, the analyte concentrations in the sample entering and exiting the membrane are equal. As a result, the surface concentration of the analyte can be directly correlated to its concentration in the sample but is no longer dependent on the volume of the sample passed through the membrane. Therefore, it is no longer necessary to meter an exact sample volume through the membrane. The main innovation herein lies in integrating the high sensitivity and selectivity of fluorescence sensors with the preconcentration capability and ND principle of SPE, which will enable quick, reliable detection of PFAS in a simple, low-cost way. The project will be implemented around three specific aims: Specific Aim 1. Synthesis and surface immobilization of fluorophores selective to either PFOS or PFOA to in-house fabricated SPE disks. Specific Aim 2. Evaluation of F-SPE/ND for PFOS and PFOA detection. Specific Aim 3. Commercialization Assessment.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

7 SBIR/STTR records share this UEI (2013–2025). Reported award amounts total $3,126,179. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense, Department of Health and Human Services, Environmental Protection Agency

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.