Explore This Research Award in CaptureIQ
Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.
Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- NEONEUR LLC
- Proposal award date
- 2022-09-08
- Contract end date
- 2024-07-31
- UEI
- MV62SPVVD5B3
- Solicitation number
- PA20-262
- Topic code
- 600
Research abstract
Summary Abstract
Neoneur 921494 Improving High-Risk Infant care, From Hospital to Home with Neoneur
Telehealth (4.21)
The overall outcome for high-risk infants have improved significantly over the past two decades
with increased long-term survival and less major morbidities. The focus has shifted to defining
outcomes according to the quality of survival, with neurodevelopmental impairments being one
of the hallmarks of both prematurity and major congenital anomalies. Feeding remains a major
challenge for nursing care of high-risk infants, many who start life with a feeding tube. Poor
feeding is the most common reason for delayed discharge. Safe oral feeding is a particular
challenge for premature infants, and those born with complex congenital disorders, many of
whom are fed via a nasogastric tube initially or during recovery after surgery. Unlike other
critical physiological parameters currently there is no quantitative means to measure adequate
infant maturation (for the preterm infant) or recovery (for the cardiac infant) to safely transition to
oral feeding without respiratory risk. The Neoneur is a hand-held, mobile device, which uniquely
(issued patents 8473219, 8413502) measures patterns of oral cavity pressure, synchronized
with respiration providing the clinician with a quantitative assessment of feeding patterns. In
2019, Neoneur, LLC completed over 150 clinical interviews as part of the national I-Corps
program (NSF 1844816). Based on these interviews we hypothesize Neoneur’s measurements
are biomarkers that will improve quality of care and transitions to oral feeding, and by enabling
telehealth evaluation infants will get home earlier and decreases necessity for rehospitalization
due to poor weight gain. The technical effort supported by this proposal will advance the
capability of the Neoneur to provide the following: utility in the clinical setting, a means for
remote telehealth evaluations, demonstrated correlation to clinical relevance in infant specific
measurements and tracking, improve FDA application and claims, advance market adoption,
and investor readiness. This Fast-Track SBIR proposes to transform a research into a clinically
relevant device through the following aims. Phase l -upgrade prototype for manufacturability, -
clinical cleanliness, and telehealth functionality: Phase II - scale manufacturing, and performing
a study to assess safety and clinical value/utility. We will enroll 140 preterm infants and 140
infants with complex congenital heart disease and follow them from initiation of oral feeding in
the hospital and continue in the home for a maximum total of 12 weeks.
Technology keywords
Not reported
Other awards by this recipient
Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
Research funding history
2 SBIR/STTR records share this UEI (2022). Reported award amounts total $1,959,107. Reported amounts are not federal obligations.
Phases: Phase II, Phase I
Agencies: Department of Health and Human Services
Agency intelligence
Department of Health and Human Services
Back to SBIR/STTR Research Awards