SBIR/STTR Research Award

Low Hazard Heat Pump for Distributed Cooling

Award identifier d7de3306d5f7d0ddfa89bb325f4a1d600173ca86f06431b8a054e7d780e02d79Awarding agency Department of Defense · Navy

Award amount

$140,000

Program and phase

SBIR · Phase I

Award year

2022

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Defense
Branch
Navy
Recipient company
THE COLUMBIA GROUP INC
Proposal award date
2022-08-08
Contract end date
2023-02-10
UEI
TMEKKBCYLSR1
Solicitation number
22.1
Topic code
N221-052

Research abstract

The standard US Navy cooling system provides 44°F chilled water throughout the ship. The US Navy seeks an innovative heat pump to support development of a distributed cooling architecture and topology where centralized chillers provide 67°F cooling water (instead of the 44°F chilled water). The water temperature is then reduced at point-of-service to 42-44°F (where needed) for air conditioning purposes. The net result is a more efficient cooling system onboard. Team TCG believes the most viable solution is a thermoelectric module. The thermal performance requirements for the low hazard heat pump are demanding. The design approach is to make use of a thermoelectric water to water module. This design approach is based on a trade study conducted by Team TCG which demonstrated that Thermoelectric modules would be the preferred solution over a more traditional mechanical refrigeration cycle. Team TCG proposes to design a thermoelectric heat pump to meet the requirements of the low hazard heat pump. In Phase I, a subscale test device will be constructed. The Phase I system will be tested at Team TCG facilities. The Phase I test device will collect the following data for each of two different manufacturer’s thermoelectric modules: -Heat transfer as a function of voltage applied and the fluid temperature differential. -Coefficient of performance as a function of water temperature and applied voltage (current). -Determination of the thermal resistance between the thermoelectric cell and the fluid (water). The collected data will be used to determine the minimum physical heat transfer volume to obtain the required COP for the Phase II prototype. The total heat transfer volume includes the thermoelectric stack and cold plates. The required volume will then be used to create a 3D model with a physical arrangement that meets the dimensional requirements.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

4 SBIR/STTR records share this UEI (2014–2022). Reported award amounts total $889,353. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense

Agency intelligence

Department of Defense

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.