Visual acuity and functional measurements in the aging eye

Award identifier 84d1c8e65731c181a79b5f088bd5808c9305bcdbcf611fb7499054b040f7dd1cAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,359,669

Program and phase

SBIR · Phase II

Award year

2022

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
AEON IMAGING LLC
Proposal award date
2022-06-01
Contract end date
2024-04-30
UEI
DLCKKJYC7NK3
Solicitation number
PA21-259
Topic code
100

Research abstract

Project Summary Age-related macular degeneration (AMD) remains the most common cause of permanent vision loss in the US and many industrialized countries. Diabetic retinopathy and diabetic macular edema are the leading cause of visual acuity loss in working age Americans. Visual function is a key component in almost all of the 1,861 US clinical trials for AMD and 262 for diabetic retinopathy and macular edema. If outcome measures, including visual acuity, could be made more accurate and cost-effective and with decreased test-retest variability, then clinical trials could use smaller sample sizes, giving savings in cost and time to bring therapies to market. By building a new device, the Potential Vision Tester™ (PVT), we will improve measurements by minimizing the issues from the optics of the aging eye. Simultaneous retinal imaging will clarify fixation locus and fixation stability of the patient’s eye. The optical errors of a patient’s eye will be measured as wavefront aberrations, and the target display will be corrected with moderately priced adaptive optics to overcome retinal elevation from exudation as well as refractive error. Reporting out of wavefront errors distinguishes between neural damage vs. optical issues. A high resolution display, suitable for visual acuity testing, will project stimuli onto the eye in Maxwellian view to minimize pupil size effects found in older eyes. Competing devices for microperimetry lack the resolution needed for visual acuity. We will use psychophysical techniques that are rapid, accurate, and provide better measures of variability: 4 alternative forced choice. In Aim 1, we will build an adaptive optics-corrected PVT visual display and NIR illumination for retinal imaging. The imaging light is comfortable and dim enough not to interfere with visual tasks. The patented NIR imaging technology projects a series of stripes onto the retina in a raster pattern, providing line scanning for imaging. The detection is via a 2D CMOS detector with a rolling shutter, with the serial read-out of the lines either synchronized with the illumination or offset in time. This provides a flexible electronic aperture under computer control. Both confocal and multiply scattered light images are available, revealing drusen and other subretinal thickening. We will optimize image quality in 10 subjects with a range of refractive error, ocular pigmentation, and age. In Aim 2, we will quantify and validate the Hartmann-Shack wavefront measurements of the PVT in 20 patients with retinal disease vs. 20 without to determine the effect on wavefront measurements. In Aim 3 we will optimize the algorithm for efficient testing and metric for Potential Visual Acuity (PVA), using data from Aims 1 and 2, reporting central tendency (expected value) and variability, including optical errors and fixation data, to address the acuity this patient could reach with retinal treatment. In Aim 4, for 20 patients with exudative AMD and 20 with diabetic macular edema, we will assess PVA reproducibility and validity by comparison to standard VA and the prediction at baseline to actual post-treatment measured VA and PVA at follow up.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

15 SBIR/STTR records share this UEI (2008–2022). Reported award amounts total $9,106,826. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.