SBIR/STTR Research Award

Visible-light optical coherence tomography for clinical glaucoma management

Award identifier 6d337046ea8dee56f3f9fcc5e57e62d9b55bc6a07cc5726f7077d1bff4de3f95Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,485,254

Program and phase

SBIR · Phase II

Award year

2022

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
OPTICENT, INC.
Proposal award date
2022-06-01
Contract end date
2024-05-31
UEI
ZJJSNNW9BY46
Solicitation number
PA21-259
Topic code
NEI

Research abstract

Project Summary This SBIR Phase IIB project focuses on developing, characterizing, and validating the next-generation clinical visible-light optical coherence tomography (vis-OCT) as a clinical tool to improve the clinical management of glaucoma. The new vis-OCT (Aurora X3) by Opticent, Inc. will offer 1.3-µm axial resolution at an A-line rate of up to 250 kHz. The new Aurora X3 system embodies a newly-designed red laser scanning internal eye fixation and a fully integrated near-infrared scanning laser ophthalmology with a principally new balanced-detection vis- OCT, which approaches shot-noise limited imaging for the first time. The adoption of Aurora X3 will address two unmet needs in clinical glaucoma diagnosis and detection of progression: (1) the ability to measure retinal sublayer structure and (2) to accurately assess local retinal hemoglobin oxygen saturation (sO2). The earliest structural changes in glaucoma are thought to be retracting retinal ganglion cell (RGC) dendrites in the inner plexiform layer (IPL). Identifying loss of synapses, either by decreased scattering or by the change in IPL sublayers’ thicknesses, could serve as an earlier and more sensitive biomarker for glaucoma than any other clinical standard. Measuring retinal sO2 and specific arteriole-venule couplets can determine the oxygen extraction in the regions served by those vessels, and our preliminary data indicate that regions showing damage in glaucomatous eyes have lower oxygen extraction than similar areas in healthy eyes. This observation suggests that such oxygen extraction abnormalities can be measured well beyond the “floor effect” threshold noted with conventional OCT, allowing assessment of disease beyond the time point that conventional structural OCT becomes insensitive. This project will conduct a multi-site clinical test using the latest Aurora X3 clinical vis-OCT at New York University, Stanford University, and University of Virginia to validate the proposed IPL and sO2 biomarkers in glaucoma.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

6 SBIR/STTR records share this UEI (2016–2023). Reported award amounts total $3,602,765. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, National Science Foundation

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.