SBIR/STTR Research Award
Plug-and-Play High-Order B0 Shimming for Reliable Temporal Lobe Epilepsy Magnetic Resonance Spectroscopic Imaging
Award amount
$699,262Program and phase
SBIR · Phase IAward year
2021Award details
- Awarding agency
- Department of Health and Human Services
- Branch
- National Institutes of Health
- Recipient company
- LUCIDITY MEDICAL, LLC
- Proposal award date
- 2021-09-22
- Contract end date
- 2023-08-31
- UEI
- JUTDSUN5T9W5
- Solicitation number
- PA20-260
- Topic code
- 103
Research abstract
Abstract:
Epilepsy affects 7 million people globally, and the temporal lobe epilepsy (TLE) is its most common form. For
TLE patients that are undergoing surgical treatment, functional neuroimaging is vitally important to localize
epileptic focus, maximize the preservation of unaffected areas, and optimize post-surgical outcomes. MR
spectroscopic imaging (MRSI) is a promising modality to directly localize abnormalities of metabolites and
neurotransmitters in the epileptic focus. To date, multiple clinical studies have demonstrated the prognostic
value of MRSI in post-surgical outcomes for TLE and other neurological disorders such as glioblastoma and
brain trauma. However, the MRSI image reliability is often impaired by the insufficient B0 field homogeneity in
a certain region of the brain. Particularly, the susceptibility mismatch between the air in the sphenoid sinus and
temporal lobe(TL) leads to local B0 field distortion, hence disrupt the spectral quality in a major portion of the
TL. Although state-of-the-art MRI scanners are equipped with B0 field correcting capability (B0 shimming), it
can only correct for slow varying fields and not the higher-order field disturbance at the tissue/air interfaces. In
order to provide accurate and reliable MRSI for the temporal lobe, a reliable high-order B0 shimming device
that can fit into clinical workflow is highly desirable. There are limited options in the market of high-order B0
shimming devices. The available products are usually too heavy and too complicated to be adopted in a
routine clinical setting. In this proposal, we propose a lightweight high-order shim coil that provides reliable
whole TL MRSI coverage under standard clinical workflow. Adopting the surface shim/RF coil technology,
lightweight coil components, and optimized interface design, a plug-and-play high-order B0 shim coil will be
developed and integrated into a clinical high field scanner. The endpoints of this proposal will lay the
foundation to enable clinical high-order B0 homogeneity in high field clinical scanners. This will facilitate the
clinical translation of state-of-the-art MRSI for temporal lobe epilepsy and other major neurological diseases.
Technology keywords
Not reported
Awards with the same topic code
Verified by an exact topic code match. This is not a text-similarity match.
- Developing virtual reality programs to address social skills deficits in youth with ADHD
- Commercialization readiness of motion-robust brain MRI for pediatric healthcare
- Improved flow cytometry panel design with a novel automated panel design system
- Time-resolved laser speckle contrast imaging of resting-state functional connectivity in neonatal brain
- Using Machine Learning and Sensing to Contextualize Hyperactivity Measurement on Wearable Devices