SBIR/STTR Research Award

An Intraperitoneal Insulin Delivery System for Management of Type 1 Diabetes

Award identifier 1948c198b21241a313226925c621cc65e0f0112058026578500da51a6473246dAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$2,041,419

Program and phase

SBIR · Phase II – Direct to Phase II

Award year

2021

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
PERIKINETICS INC
Proposal award date
2021-09-20
Contract end date
2023-08-31
UEI
FV33R9Z4ND32
Solicitation number
PA20-260
Topic code
200

Research abstract

ABSTRACT Perikinetics’ intraperitoneal (IP) insulin delivery system for the management of Type 1 diabetes (T1D) utilizes an innovative implantable port-catheter system accessed by a proprietary external infusion set to provide a safe and effective means of tight glycemic control. For the 1.6 million Americans living with T1D, modern technological advances have improved glucose sensing and insulin delivery, however, achieving tight glycemic control remains challenging. The IP cavity presents a superior location for insulin delivery for T1D patients. IP insulin delivery better mimics physiological delivery by providing a higher insulin concentration in the portal system, enabling rapid absorption by the liver, and a more effective response to glycemic disturbances and reduced hypoglycemic episodes. Continuous IP insulin infusion (CIPII) systems developed to date have demonstrated dramatic improvement in glucose regulation but, unfortunately, suffer from catheter obstruction, infection, and aesthetic disfigurement. No FDA approved CIPII systems are currently available in the U.S. Improving the safety and clinical utility of IP insulin devices would enable commercialization of a superior option for glycemic control within a tighter monitoring range. Perikinetics (PK) has developed the PK Insulin Delivery Conduit (IDC), an implantable port-catheter system accessed by a proprietary external infusion set for IP insulin delivery. In our Phase I equivalent research studies, we established feasibility of the system through in vitro flow characterization, implant viability, and mechanical integrity testing. The overall objective of this proposal is to demonstrate that the PK IDC can safely and effectively deliver basal and bolus insulin in a T1D animal model. In Specific Aim 1, we will assess insulin stability on the bench to ensure that injected insulin will not be adversely affected by the device or delivery method. In Specific Aim 2, we will conduct a pilot animal study to validate safety, efficacy, and clinical utility of the PK IDC. Successful completion of these aims will position the device for IDE-enabling studies and, ultimately, de novo 510(k) clearance as the first IP insulin delivery vehicle using a subcutaneous port to reduce infection and improve quality of life.

Technology keywords

Not reported

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.