SBIR/STTR Research Award

Quantitative oxygen sensing to enable personalized oncology treatment planning

Award identifier 91fa83719774e7827103f7de3c4a88002351d7c5e463daa7c111842f1eb07a63Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$399,740

Program and phase

SBIR · Phase I

Award year

2021

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Stratagen Bio, Inc.
Proposal award date
2021-09-15
Contract end date
2022-08-31
UEI
U88TTMK6HUM4
Solicitation number
PA20-260
Topic code
102

Research abstract

Project Summary and Abstract Tumor oxygen levels are predictive of outcomes for patients receiving radiation therapy for cervical cancer. The effectiveness of radiation therapy is controlled by tumor oxygen with reduced effectiveness occurring in low oxygen regions. The survival rate for cervical cancer patients with a low oxygen tumor is 40% less than for patients with an oxygenated tumor. Resistance to therapy can be overcome by delivering an elevated dose of radiation. Existing oxygen sensing techniques cannot enable this treatment personalization because they are either impractically invasive or are indirect and qualitative. An appropriate dose escalation technique should enable localized delivery of elevated doses to only the low oxygen regions of a tumor. Interstitial high dose rate (HDR-brachy) is part of the current standard of care for many cervical cancer patients and involves the short- term placement (1 to 3 days) of plastic catheters (up to 30+, 2 mm diameter hollow tubes) throughout the tumor to serve as conduits for the temporary placement of radioactive seeds. Dose distribution is controlled by seed position and dwell time within the catheters which allows for hyper-localized and well-controlled dose escalation. The proposed oxygen sensor will address the unmet medical need for direct and quantitative measurements of tumor oxygen. This sensor leverages a proprietary oxygen sensing polymer, is made completely of silicone and is passive, wireless, and measured non-invasively using magnetic resonance imaging (MRI). This leverages the growing trend of using MRI during treatment planning and the catheter placement of HDR-brachy catheters. In the United States, MRI use has increased from 2% in 2007 to 34% in 2014, and it is the recommended imaging modality throughout Europe. The proposed device format is a new HDR-brachy catheter that includes the oxygen sensing polymer on the outside surface to achieve multiple discrete oxygen measurements along the length of the device, fast equilibration with tissue oxygen, and has a fully functional inner channel for radioactive seed placement. This will combine the ability to measure tissue oxygen levels and hyper-localize dose escalation. It will leverage the current standard of care to provide clinicians with actionable and easy to interpret oxygen measurements to personalize and improve clinical decisions. This sensor format is also readily translatable to other cancers treated with HDR-brachy and where patients suffer from treatment resistance and poor outcomes tied to low oxygen levels including prostate and head and neck cancers.Project Narrative Low tumor oxygen levels reduce the effectiveness of all common types of treatment and lead to poor outcomes. The lack of direct and quantitative oxygen sensing techniques prevents the implementation of therapies to address and overcome low oxygen tumor resistance. The proposed oxygen sensor would enable quantitative and direct measurements of tumor oxygen and allow for more personalized and effective treatment.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

2 SBIR/STTR records share this UEI (2021–2023). Reported award amounts total $799,628. Reported amounts are not federal obligations.

Phases: Phase I

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.