SBIR/STTR Research Award

Development and evaluation of novel high-density intracortical microelectrode arrays for clinical applications

Award identifier 42d6ed3a4fcf0486cffc6d4e58a01577ba71120c68b436fd121cc16781deaaf0Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$3,156,162

Program and phase

SBIR · Phase II – Direct to Phase II

Award year

2021

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
Paradromics, Inc.
Proposal award date
2021-09-10
Contract end date
2024-08-31
UEI
MD3CFK6J7ZQ4
Solicitation number
PA18-566
Topic code
101

Research abstract

PROJECT SUMMARY Paradromics is developing high data rate brain computer interface technologies as a platform for medical device applications. In our Phase I SBIR, we designed, built, and tested a neural recording system based on massively parallel microwire electrode arrays bonded to CMOS readout electronics. That system supports up to 65,536 active electrode channels sampled simultaneously at over 32,000 Hz. We used this system to record action potentials from arrays of up to 1200 microelectrodes in rats (penetrating, 1mm depth) and local field potentials from rt30,000 microelectrodes in sheep (surface). This serves as a demonstration of the microwire- to-CMOS bonding architecture that will form the core of our next device, a medical implant. For this new implantable medical device, we have developed a new and substantially improved method of electrode array fabrication. This method produces more ordered, regular arrays through Electrical Discharge Machining (EDM), thus improving on the stochastic connections of the bundle architecture from Phase I with the ability to be produced under GMP. A new, custom CMOS sensor, also developed following the NIH SBIR Phase I effort, performs compressive sensing of neural data to reduce power and data requirements in the future device. As we prepare to build this implantable medical device and take it to market, it is critical to extensively test the insertion reliability of different arrays designs in order to produce a device best optimized for insertion and recording. Here we propose to use passive arrays of 400-1600 electrodes, smaller than our Phase I approach, to find the optimal electrode array design for clinical translation. We will test array designs that can reliably insert into the sheep cortex, validate the insertion of that array in human tissue intraoperatively (under IRB), and evaluate the tissue response to the array over a period of up to 6 months, implanted chronically in sheep. The overall goal for the future array is to ensure that we can reliably insert the array with the smallest shank width to mitigate the chronic foreign body response at an appropriate pitch (100 - 400 μm) and length (i.e. 1 mm) suitable for the human cortex. Moreover, this data will also be critical for designing certified GLP studies, and for planning conversations with the FDA for pre-IDE meetings, where we will need a finalized array design and testing plan in place. The aims of this Direct to Phase II study are as follows: Specific Aim (SA) 1: Determine optimal microelectrode array design and validate implantation in sheep and human cortical tissue intraoperatively with passive arrays of 400-1600 electrodes. We aim to better understand how the geometric parameters of high density microwire electrode arrays impact insertion reliability into cortical tissue in vivo in an ovine (sheep) model (SA 1.1), with refined geometries implanted intraoperatively into human cortex (SA 1.2). Specific Aim 2: Determine long-term viability of implanted, passive arrays in sheep. . We will determine the long-term viability of our high-density array by chronically implanting the passive arrays in sheep. Animals will be implanted over 4, 8, 12, and 24 weeks. The degree of glial scarring and neuron loss will be compared around electrodes between high-density and commercial arrays over these timepoints.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

2 SBIR/STTR records share this UEI (2016–2021). Reported award amounts total $3,953,933. Reported amounts are not federal obligations.

Phases: Phase I, Phase II – Direct to Phase II

Agencies: Department of Health and Human Services

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.