SBIR/STTR Research Award

Rapid 3D Whole-Slide Digitization of Thick Cytopathology Slides with a Gigapixel Microscope

Award identifier 364e8aedc85124fdee3b8b86638b5013c960f9ce00503595793fdc29fe3f4fc7Awarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$2,000,000

Program and phase

SBIR · Phase II

Award year

2021

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
RAMONA OPTICS INC
Proposal award date
2021-09-01
Contract end date
2023-08-31
UEI
MR4ZCJJQHHP5
Solicitation number
PA19-272
Topic code
102

Research abstract

Significance: Digital microscopes are becoming an indispensable tool within the pathology lab. Whole-slide microscope scanners are now routinely used to record gigapixel-sized images of surgical pathology specimens for archival, sharing, annotation and automated processing. Unfortunately, whole-slide scanners still cannot efficiently digitize thick specimens, such as fine-needle aspirates (FNAs) and other cytology samples that are commonly used as the first-line modality for diagnosing cancer of the lung, thyroid, pancreas and other sites. Standard microscope lenses can only capture data from a 1 mm2 area per snapshot. Given this limitation, it is currently not technically feasible to fully scan out an entire slide in 3D, which leads to a number of critical bottlenecks within the cytologist's workflow for cancer diagnosis. Proposal: Ramona Optics is developing a new micro-camera array microscope (MCAM) that can overcome these limitations to digitize thick specimens (up to 50 µm deep) at 1 µm3 volumetric resolution across an entire slide. The resulting multi-gigabyte recording can then be examined by cytopathologists via a custom-developed 3D software interface to aid with various diagnostic tasks. In Phase I of this Fast-Track proposal, Ramona will finalize the hardware and software for its new MCAM-3D device. In Phase II, Ramona will collaborate with the Duke University Medical Center and several other cytopathologists to test and measure MCAM-3D performance on several relevant clinical tasks, including remote telecytology-based assessment of FNA sample adequacy, as well as suitability for secondary diagnosis. Apart from improving workflow and patient care in the hospital, Ramona Optics also expects the MCAM- 3D to enable a number of critical high-throughput imaging experiments in the life sciences that are currently not possible due to the limited throughput of current standard microscope designs.SA1 (Phase I): Integrate hardware and software for whole-slide MCAM-3D capture: Ramona will complete development of an MCAM-3D device that digitizes whole slides (12 cm2 area, 50 µm thick) at 0.8 and 2.6 µm/pixel lateral and axial resolution within 1.5 minutes. 3D viewing software will enable real-time interaction with the multi-gigabyte recorded data volume, offering ~50X more measurements than current 2D whole-slide scanners.SA2 (Phase II): Evaluate MCAM-3D for telecytology and improve system specifications: In collaboration with 3 cytopathologists at the Duke University Medical Center, Ramona will test the MCAM-3D for remote rapid on-site evaluation (ROSE) of sample adequacy. ROSE is well-known to improve patient care by reducing repeat procedures. The objective of this aim is to show that the MCAM-3D can make ROSE easier, quicker and potentially more accurate. At the same time, Ramona will incorporate study findings to improve lateral/axial imaging resolution to 0.5 µm/1 µm and scanning speed to 30 sec.SA3 (Phase II): 3D whole-slide digitization and remote viewing for clinical applications: Ramona will improve the MCAM-3D's processing speeds to enable real-time remote viewing of 3D samples within the Duke University Medical Center. It will then work with cytopathologists to carefully assess its performance at telecytology-based diagnoses and archiving specimen material as it works towards a finalized product for sale 6 months after the conclusion of this project.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

12 SBIR/STTR records share this UEI (2017–2025). Reported award amounts total $11,552,328. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Health and Human Services, National Science Foundation

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.