SBIR/STTR Research Award

Non-Contact High-Resolution All-Optical Handheld Ultrasound Imaging System

Award identifier 8b55f5e39ccf33d82cbcb6a62757217ac618c51d2e13a10bd943fe680f2e3150Awarding agency Department of Defense · Defense Health Agency

Award amount

$249,898

Program and phase

SBIR · Phase I

Award year

2021

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Defense
Branch
Defense Health Agency
Recipient company
BRIMROSE TECHNOLOGY CORP
Proposal award date
2021-08-24
Contract end date
2022-03-23
UEI
WKDYRE26KLT7
Solicitation number
21.1
Topic code
DHA211-012

Research abstract

We propose the development of designs for a handheld, non-contact Laser UltraSound (ncLUS) Imager that enable rapid triage by combat medics. The proposed development work relies on the photoacoustic generation of ultrasound waves and the deployment of a second laser and the Speckle-Tolerant Photo-EMF Sensor for detecting back-scattered ultrasound waves. We aim to design the ncLUS imager with characteristics meeting the Government’s specifications in terms of form factor, weight, computational power, ultrasound image refreshment rate, operational time duration, and the standoff distance of 1 meter. We propose to develop the ncLUS design by approaching four sub-systems of the ncLUS Imager: opto-mechanical, opto-electronic, data processing/ultrasound image formation, as well as electronics sub-system. These four sub-systems enable non-contact laser scanning and ultrasound generation, non-contact back-scattered ultrasound detection, data processing/computation for image formation, and the driving/synchronization/triggering circuitry, onboard computer, data storage, wireless communication, and battery management. The proposing team leverages Brimrose’s expertise in photonics device/system development, design, and manufacturing, as well as Professor Boctor’s (Johns Hopkins University) leading expertise in ultrasound imaging and ultrasound technology development. Detailed designs for the ncLUS Imager will be delivered to the Government at the end of program.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

56 SBIR/STTR records share this UEI (2010–2025). Reported award amounts total $23,415,654. Reported amounts are not federal obligations.

Phases: Phase I, Phase II

Agencies: Department of Defense, National Aeronautics and Space Administration, Department of Energy, Department of Health and Human Services

Agency intelligence

Department of Defense

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.