SBIR/STTR Research Award

Ultra-dense and Fast Ceramic Scintillator for PET

Award identifier dfcb0b17dfaf15871779b991ab988105ecea5094f96ebbee3f677bad9393e5fdAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$1,302,118

Program and phase

SBIR · Phase II

Award year

2021

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
RADIATION MONITORING DEVICES, INC.
Proposal award date
2021-08-01
Contract end date
2023-07-31
UEI
SCKQA85YU4U4
Solicitation number
PA19-272
Topic code
102

Research abstract

Project SummaryThe current detector technology in PET requires scintillation that has fast response, excellent timing resolution, high detection sensitivity, good energy resolution, and last but not least acceptable cost. At present, most PET systems use crystals of LSO (Lu2SiO5:Ce) or its analog LYSO, which satisfy many of the listed requirements. But LSO, after years of development, has reached its performance limit, especially for the scanners with a long axial field of view (AFOV) that are currently being developed. The goal of these scanners is to increase the geometrical coverage and significantly increase detection sensitivity (by a factor of 30-40), thereby reducing the scanning times (30-40 times faster) or the patient's radiation exposure.However, long AFOV scanners face two main challenges: greater depth-of-interaction (DOI) effects, which increase blurring and noise; and an increase in the volume required for the constituent crystals, which make up some 50% of the cost of the entire scanner. The use of shorter crystals can counteract both the DOI effects and the increased crystal volume (hence cost), but with a major loss of detection efficiency, defeating the original purpose. Another approach for reducing DOI effects is a double-ended read-out but this increases both cost and system complexity. Therefore, to achieve viable and affordable long AFOV scanners, a new scintillation material is required that would provide higher stopping power than LSO, with similar or better timing properties, and at a lower cost.These requirements can be met by a scintillator based on Lu2O3. This host has a very high density (9.4 g/cm3 vs. 7.4 g/cm3 for LSO) and an effective Z of 68 vs. 65. When doped with Yb3+, it exhibits an ultra-fast charge transfer (CT) luminescence with decay time on the order of 1 ns, substantially faster than the 40 ns of LSO. While the material's light yield is low, its timing properties are excellent with better than 250 ps resolution FWHM when paired with LaBr3:Ce. The only property where the material is deficient is its energy resolution (rt15% at 511 keV, due to its low light yield). Fortunately, this shortcoming can be addressed by double doping, which increases its light yield to about 20,000 ph/MeV. In this project, we plan to optimize the doping content of Lu2O3 so as to maximize its scintillation properties and achieve energy resolution of about 8% at 511 keV and timing resolution of 200 ps. In Phase II we will increase the volumes of produced material, develop cost reduction schemes, and produce and evaluate PET detection modules with the same performance goals.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Research funding history

930 SBIR/STTR records share this UEI (1983–2026). Reported award amounts total $346,950,619. Reported amounts are not federal obligations.

Phases: Phase I, Phase II, Phase II – Direct to Phase II

Agencies: Department of Energy, Department of Health and Human Services, Department of Defense, National Aeronautics and Space Administration, National Science Foundation, Department of Homeland Security

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.