SBIR/STTR Research Award

Development and evaluation of diffuse correlation spectroscopy to monitor cerebral blood flow and detect intraventricular hemorrhage in extremely premature infants

Award identifier b3ddbe9820e44f0369ae7297c62af5e50fbd5280e1cab4b0a4f1cd8230250cfcAwarding agency Department of Health and Human Services · National Institutes of Health

Award amount

$998,872

Program and phase

STTR · Phase II

Award year

2021

Explore This Research Award in CaptureIQ

Research the technology, evaluate the recipient and agency, identify related opportunities, and explore potential follow-on work with CaptureIQ.

Award details

Awarding agency
Department of Health and Human Services
Branch
National Institutes of Health
Recipient company
149 MEDICAL INC
Proposal award date
2021-06-01
Contract end date
2023-05-31
UEI
P3CACVT5FJG6
Solicitation number
PA18-574
Topic code
103

Research abstract

PROJECT SUMMARY/ABSTRACT Every year in the United States about 30% of the 60,000 infants born extremely premature (andlt;30 weeks gestational age and andlt;1000 g birth-weight [ELGA]) develop intraventricular hemorrhage (IVH). IVH is associated with high risk for cerebral palsy and significant intellectual disability, causing lifelong implications for affected children and their families and considerable economic burden. IVH is caused by the rupture of the fragile capillaries in the germinal matrix which cannot withstand fluctuations in cerebral blood flow (CBF). In andgt;90% of cases, these injuries occur during the first three postnatal days during a period of cardiorespiratory instability that has a direct effect on CBF, which results in periods of cerebral hypo- and hyper-perfusion. Current management strategies, such as changes in ventilation or inotrope support, are blind to the impact on CBF. Improved bedside technologies to continuously monitor CBF are urgently needed to allow the clinician to make informed decisions, to optimize current strategies and foster the development of new interventions to reduce the incidence of IVH in ELGA infants and to improve developmental outcomes. Building on 149 Medical founding team’s ten years of success measuring infants with non-invasive bedside optical methods, we propose to design and build a novel fast multi-distance diffuse correlation spectroscopy (DCS) system, optimized for continuous monitoring of CBFi in ELGA infants. DCS directly quantifies an index of cerebral blood flow (CBFi) by measuring the temporal fluctuations of light generated by the dynamic scattering of moving red blood cells. To be of use in the ELGA infant, this bedside monitor needs to be safe, continuous, precise, reliable, quantitative and gently wearable. These pre-requisites will be met by designing an optical sensor which can be gently applied to the ELGA infant. The novel DCS system will be initially tested by the 149 Medical’s team in phantoms to verify performance and demonstrate precision and accuracy of flow estimates. The system will then be tested in more mature, stable premature infants at the Brigham and Womenandapos;s Hospital (BWH) NICU to evaluate feasibility of long measurements, compatibility with the NICU environment, skin integrity after long monitoring periods, and in-vivo algorithm validation. Finally, the device will be used in 50 ELGA infants during the first 72 hours of life to test our hypothesis that DCS-measured CBFi fluctuations and pressure-passive events correlate with incidence and severity of IVH. Our goal is to provide a much-needed cerebral blood flow monitor to guide individualized treatment with the goal of reducing the risk of IVH and improving long term neurodevelopmental outcomes among ELGA infants. This study in 50 ELGA infants will set the stage for a larger trial alongside commercialization.PROJECT NARRATIVE There is a great need for a bedside, non-invasive and continuous neuromonitoring tool to provide a robust measure of cerebral blood flow in premature infants. We propose to develop a novel near-infrared diffuse correlation spectroscopy (DCS) system optimized for monitoring of the cerebral blood flow index in extremely premature infants. The successful development, validation and demonstration of clinical feasibility and effectiveness of our proposed technology will lead to new patient management approaches for reducing neurological injury, protecting neurocognitive function, and reducing the overall morbidity and mortality associated with prematurity.

Technology keywords

Not reported

Other awards by this recipient

Verified by the same UEI. These are other public SBIR/STTR award pages, not a merged company record.

Awards with the same topic code

Verified by an exact topic code match. This is not a text-similarity match.

Agency intelligence

Department of Health and Human Services

Back to SBIR/STTR Research Awards

Don't take our word for it. Ask AI about RFPCapture.

See what leading AI assistants have to say about RFPCapture and CaptureIQ.

Gemini opens without a prefilled question. The question is copied to your clipboard when the button works. You can also copy it here:

What is RFPCapture.com and its CaptureIQ platform from Smart Logic AI? How does it help federal contractors discover opportunities, evaluate bid/no-bid decisions, research government contracts, and prepare proposals? How does it compare with other federal capture platforms? Use independent sources where available.